Back to search

Aristotle University Of Thessaloniki (AUTH)

Συγκριτική μελέτη ασφάλειας και αποτελεσματικότητας απορροφήσιμων και μη υλικών καθήλωσης πλεγμάτων μετά από ενδοπεριτοναϊκή τοποθέτηση: πειραματική μελέτη σε χοίρους

Abstract

dc:description

Purpose: Choice of the best possible fixation system in terms of safety and effectiveness for intraperitoneal mesh placement in hernia surgery remains controversial. The aim of the present study was to compare the performance of four fixation systems in a swine model of intraperitoneal mesh fixation.Methods: Fourteen Landrace swine were utilized in the study. The experiment included two stages. Initially, four pieces of mesh (VentralightΤΜ ST) sizing 10 × 5 cm were placed and fixed intraperitoneally to reinforce 4 small full thickness abdominal wall defects created with diathermy. These defects were repaired primarily with absorbable suture before mesh implantation. Each mesh was anchored with a different tack device between AbsorbatackTM, ProtackTM, CapsureTM, or OptifixTM. The second stage took place after 60 days and included euthanasia, laparoscopy, and laparotomy via U-shaped incision to obtain the measurements for the outcome parameters. The primary endpoint of the study was to compare the peel strength of the compound tack/mesh from the abdominal wall. Secondary parameters were the extent and quality of visceral adhesions to the mesh, the degree of mesh shrinkage and the histological response around the tacks. Results: Thirteen out of 14 animals survived the experiment and 10 were included in the final analysis. CapsureTM tacks had higher peel strength when compared to AbsorbatackTM (p = 0.028), ProtackTM (p = 0.043) and OptifixTM (p = 0.009). No significant differences were noted regarding the extent of visceral adhesions (Friedman’s test p value 0.854), the adhesion quality (Friedman’s test p value 0.506), or the mesh shrinkage (Friedman’s test p value = 0.827). Four out of the ten animals developed no adhesions at all 2 months after implantation. Conclusion: CapsureTM fixation system provided higher peel strength that the other tested devices in our swine model of intraperitoneal mesh fixation. Our findings generate the hypothesis that this type of fixation may be superior in a clinical setting. Clinical trials with long-term follow-up are required to assess the safety and efficacy of mesh fixation systems in hernia surgery.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kapoulas, Spyridon
  • Καπούλας, Σπυρίδων

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/51460

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kapoulas, Spyridon; Καπούλας, Σπυρίδων. Συγκριτική μελέτη ασφάλειας και αποτελεσματικότητας απορροφήσιμων και μη υλικών καθήλωσης πλεγμάτων μετά από ενδοπεριτοναϊκή τοποθέτηση: πειραματική μελέτη σε χοίρους. Aristotle University Of Thessaloniki (AUTH), 2022. http://hdl.handle.net/10442/hedi/51460