Back to search

National and Kapodistrian University of Athens

Τεχνικές αγγειακών αναστομώσεων

Abstract

dc:description

Introduction. Open surgical repair remains an integral part of aortic disease treatment options. Hand-sewn anastomosis between the treated aortic segment and the graft is a crucial part of the procedure, is technically demanding and can be time-consuming even for an experienced surgeon. To achieve a faster and more automated anastomosis, several authors have experimented with the use of alternative methods such as, ringed grafts, anastomotic stents or adhesives, however, none of them have been established in everyday clinical practice. Objectives. The present study aims to explore the reasons behind this technological gap in regards to aortic end-to-end anastomosis through systematic review and meta-analysis of the studies that incorporated the use of alternative anastomotic methods in the clinical setting or under experimental conditions, as well as, through systematic on-site observation and documentation of open aortic reconstruction surgeries. Furthermore, we intented to develop and test under at the in-vitro level a novel bidirectional surgical needle in order to improve aortic anastomosis in relation to time and ease of use.Methods. (a) With regards to the systematic review and meta-analysis of the clinical studies, for each eligible study we recorded the mean aortic cross-clamping time and the corresponding standard deviation, while we retrieved or calculated valid percentages for the proportion of patients that experienced the outcome of interest, i.e., death within 30 days from the index operation. (b) Concerning the experimental studies, for each eligible study we recorded the mean total aortic anastomosis time in minutes, as well as the mean total point of rupture of the anastomosis in Newton and corresponding standard deviation. (c) To assess the current anastomotic technique, we observed and documented seven open aortic reconstruction surgeries that took place in “Laiko” General Hospital of Athens and “Attiko” University Hospital of Athens. Utilizing the collected data and applying the task analysis method we created an operation primer. (d) Finally, a novel bidirectional surgical needle was designed, developed and manufactured. The new design was assessed in an aortic anastomosis experimental model, in comparison with the conventional one in relation to the time required to complete an anastomotic task and to the distanced travelled by the hand of the surgeon while performing the task.Results. Our meta-analysis shows that the alternative anastomotic devices which were used in clinical settings had a relatively low 30-day mortality rate (9.16%). Furthermore, the alternative anastomotic devices tested under experimental conditions, seem to reduce significantly the anastomotic time (weighted mean difference -7.24 min), however, they are also associated with a lower point of rupture (weighted mean difference -20.68 N). Through systematic on-site observation, it was observed that two out of eight micromovements during the placement of a single stitch are related to the rotation of the needle tip and remounting of the needle. The proposed bidirectional needle aims to eliminate the aforementioned maneuvers. According to the comparative fatigue analysis performed, the new needle design improves durability, provided the two tips are equally used. Polytetrafluoroethylene coating improves penetration into the tissue by 7 % to 17 %, while electropolishing improves penetration up to 19 %. Finally, when using the novel needle design, the average anastomotic task completion time was significantly reduced by 22 % and the overall distance of hand movements was significantly reduced by 20 %.Conclusion. Our results show that the alternative anastomotic devices offer a faster anastomosis, but they are inferior in terms of the tensile strength of the hand-sewn technique. We argue that the reduced tensile strength of the anastomosis created using alternative anastomotic devices contributes to late complications observed in the reviewed clinical studies. The proposed novel surgical needle, while keeping the advantages of the hand-sewn technique, exhibited shorter anastomotic time and seems promising in relation to precision, ease of use and simplicity of the anastomotic technique it introduces.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Manolesou, Danae
  • Μανωλέσου, Δανάη

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/51550

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Manolesou, Danae; Μανωλέσου, Δανάη. Τεχνικές αγγειακών αναστομώσεων. National and Kapodistrian University of Athens, 2022. http://hdl.handle.net/10442/hedi/51550