University of Ioannina
Κατανομή δόσης από φωτόνια υψηλής ενέργειας σε υλικό μικρού ατομικού αριθμού κοντά σε ανομοιογένειες
Abstract
dc:descriptionThe precise knowledge of the distribution of the absorbed dose to the irradiated volume is necessary for the success of a radiotherapy treatment. Inhomogeneities in the human body, natural or artificial, modify substantially the dose distribution at short distances due to lack of electronic equilibrium. The disturbances in the dose distribution can be substantial near interfaces with materials of different elemental composition, which is of great importance in some clinical cases.The aim of this research that was carried out at the Medical Physics Laboratory at the University of Ioannina was the experimental and computational study of dose perturbation at areas of soft tissue after interfaces with prostheses or tissue of different elemental composition during Radiotherapy with high energy X-rays. More specifically, the perturbation of dose distribution was studied, both experimentally and computationally, in a parallelepiped phantom made of PMMA (a low Z material that resembles soft tissue) at various distances from beam exit from slabs made of high Z materials inserted between PMMA slabs.To this end measurements were performed using 6 and 18 MV X-rays from a linear accelerator, the Varian Clinac DHX at the University General Hospital of Ioannina. Radiochromic films HD-810, MD-55 and ΕΒΤ3 were used for the experimental dose measurements. A flatbed scanner Microtek ScanMaker S480 was used for film scanning and digitization in the reflection mode. In addition the absorbed dose was calculated using the MCNP6 Monte Carlo code.The dose perturbation in a tissue or organ of low Z, like muscle tissue, heart and eye, following a high Z inhomogeneity (e.g. bone tissue, tooth, a surgical plaque, a pacemaker) was quantified by two dose perturbation factors (Forward Scatter Dose Factor, FSDF). The Di/Dh factor quantifies the dose perturbation in a low Z material due to the presence of the interface close to where the beam exits from the inhomogeneity, while the second factor Di/DH takes into account both influence of the interface and the differences in the attenuation and scattering properties of the two materials.Following the quality control of the developed methodologies, the following factors were studied for their influence on the FSDF: radiation field size, inhomogeneity thickness, atomic number and density of the inhomogeneity material, distance of the measurement point from the high Z - low Z interface, in 6 MV and 18 MV X-ray irradiations.The experimental data using Al, Cu and Pb inhomogeneities of various thicknesses placed in a 30 cm x 30 cm PMMA phantom, were compared to the corresponding simulation data. A satisfactory agreement was found between direct dose measurements and mathematical simulations, taking into account the related errors that are of a magnitude of 2% and 3%, respectively, allowing for additional simulations. In addition, the findings of the present study were comparable with limited published data by other investigators. Hence, confidence was built on accuracy of the simulations that were not tested experimentally.I general, the FSDF factors at various distances from the exit interface were found to be higher in the 18 MV irradiations than the 6 MV ones, and increase with increasing Z. On the other hand, both FSDF factors were found to be independent on the field size in the studied range from 3.0 cm x 3.0 cm to 20 cm x 20 cm.The Di/Dh values at the studied ~125 μm distance from the interface were less than 1.0 in the experimentally studied materials and decreased as the inhomogeneity thickness increased, in the 6 MV exposures, and higher than 1.0 in the 18 MV ones (up to 1.5 in case of Pb). The factor Di/DH was found to be lower than 1.0 decreasing with increasing thickness in the 6 MV exposures, while in case of 18 MV exposures its values are greater than 1.0 at small thicknesses and less than 1.0 in larger thicknesses, due to strong absorption in the inhomogeneity.The study of dependence of FSDF factors on the distance of the measurement point from the exit interface showed in case of the 6 MV exposures, that as the distance increases the factor Di/Dh is less than 1.0 and gradually increases approaching 1.0 at large distances. In case of 18 MV exposures, an increase in Di/Dh was found in the studied materials up to a maximum value and at a distance of about 1 mm to 10 mm remains almost stable, and decreases at larger distances approaching 1.0. The factor Di/DH decreases with distance irrespective of photon spectrum. In addition simulations were carried out to study the FSDF for inhomogeneities of identical specific thickness made of eight elements with Z higher than ten in the PMMA phantom. In the case of 6 MV exposures both factors decrease with increasing Z at the studied distances from the interface 50 μm, 125 μm and 1000 μm. On the other hand, Di/Dh increases in 18 MV exposures as Z increases at the studied distances. A similar increase in Di/DH was found at the 50 μm but at the other two, 125 μm and 1000 μm, the values were almost constant. Furthermore, the simulations showed that the Z of the inhomogeneity is the dominant factor on the FSDF, rather than its density.Combining the findings of the present study with the ones of previous studies carried out in the Medical Physics Laboratory at the University of Ioannina on the dose perturbation factor in PMMA before a high Z inhomogeneity with high Z material, it was found that when two opposite or almost opposite X-ray radiation fields are used clinically, the size of the dose perturbation near an interface is reduced because the factor after the interface is less than 1.0 and the factor before the interface is greater than 1.0 in case of 6 MV exposures. On the contrary, for 18 MV exposures both the forward and the backscattering dose factors are higher than 1.0, leading in a substantial increase in dose close to the interface.In conclusion the absorbed dose in a low Z material close to interfaces formed by materials that differ in regards to their atomic number is modified by the presence of the inhomogeneity, potentially affecting the outcome of radiotherapy treatment. The experimental findings were in line with the calculations and the limited published data, allowing for the estimation of the dose perturbation factors by interpolation techniques in geometries that may differ from the studied ones.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Katsarou, Eleni
- Κατσαρού, Ελένη
Subjects
dc:subject × 24- Δοσιμετρία ακτινοβολιών
- Ανομοιογένειες υψηλού ατομικού αριθμού
- Διεπιφάνειες
- Ιατρική Φυσική
- Ακτινοθεραπεία
- Monte Carlo προσομοίωση
- Radiation dosimetry
- High atomic number inhomogeneities
- Interface
- Medical physics
- Radiation therapy
- Monte Carlo simulation
- Φυσική
- Φυσικές Επιστήμες
- Φυσική, άλλοι τομείς
- Επιστήμες Υγείας
- Ιατρική και Επιστήμες Υγείας
- Επιστήμες υγείας, άλλοι τομείς
- Physical Sciences
- Natural Sciences
- Physics, miscellaneous
- Health Sciences
- Medical and Health Sciences
- Health sciences, miscellaneous
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/51565