Democritus University of Thrace (DUTH)
Η συμβολή της υπολογιστικής μελέτης της Αξονικής αγγειογραφίας στην κατανόηση της συμπεριφοράς του συνδυασμού διχαλωτού ενός - τεμαχίου (unibody) αορτικού ενδομοσχεύματος ePTFE με αορτική προέκταση από Dacron
Abstract
dc:descriptionBackground : The bifurcated AFX (Endologix, Inc, Irvine, CA, USA) aortic Stent – Graft is the sole unibody endograft for the management of Abdominal Aortic Aneurysms (AAA). In order to improve the AFX central sealing and clinical efficacy in challenging cases, a replacement of the central chromium – cobaltium AFX extension with a Nitinol – based proximal aortic cuff has been suggested. Yet, comparative data regarding the hemodynamic performance of this design is missing. Aim of this study was to compare the hemodynamic variability between the hybrid AFX – Endurant design, the classic AFX and Endurant endografts, in angulated and non – angulated cases based on patient-specific Computational Fluid Dynamics (CFD) simulations.Methods : 3D endograft models of 11 treated AAA cases were reconstructed from Computed Tomography Angiography (CTA) imaging data: 5 cases of AFX (cases A – E), 3 cases of the combination AFX – Endurant (cases F – H) and 3 cases of the classic Endurant design (cases I – K). The Displacement Forces (DF), the Time Averaged Wall Shear Stress (TAWSS), the Relative Residence Time (RRT), the Oscillatory Shear Index (OSI) and Helicity (h) on the main – body, the iliac limbs, and the entire stent – graft was calculated by processing the velocity and pressure fields generated by pulsatile CFD simulations.Results : The range of total DF (acting on the whole endograft structure) in the AFX, hybrid AFX – Endurant and Endurant group was 2.5–5.2N, 2.0–5.9N and 1.9–2.9N respectively, with the maximum total DF being lower for Endurant. The DF on the main-body of the classic and hybrid AFX cases were higher than the right and left iliac limbs (2.5–4.9N vs. 0.6–5.3N and 0.7–3.6N respectively). Conversely, the DF on the main-body of the Endurant cases was comparable to the force exerted on the right and left limbs. When separating the cases with respect to their neck angulation, the DF on all endograft parts (main–body, limbs) and on the endograft as a whole were lower for the hybrid AFX – Endurant group compared to the classic AFX and Endurant groups, for cases with almost straight neck. The lowest value of TAWSS in the main – body ranged from 0.01Pa (case Α) to 0.2Pa (case J). Accordingly, the lowest TAWSS value for the right limb ranged from 0.05Pa (case Α) to 7.96Pa (case Ε). The highest value for the right limb ranged from 16.6Pa (case C) to 83.9Pa (case B). With regard to the left limb the lowest values ranged from 0.13Pa (case G) to 2.27Pa (case Ε). Accordingly, the highest values for the left limb ranged from 7.92Pa (case D) to 59.9Pa (case Ε). High TAWSS values were detected only in a narrow zone in the caudal segment of the main – body, while the proximal segment showed very low values. The range of RRT values (on the whole endograft structure) in the classic AFX, hybrid AFX – Endurant and Endurant groups was 4.3% – 35.6%, 4.32% – 10.7% and 5.4% – 10.1% respectively. High values of OSI (>0.4) were documented in the proximal segment (neck – proximal cuff) of cases D, E, F, G, H, as well as in C. The – main body presented the highest OSI compared to the other endograft parts. The high OSI values were detected exclusively on the posterior surface of the main – body in 3/11 cases, on the anterior surface of 2/11 cases while on both surfaces in 5/11 cases. The highest and lowest values of helicity (h2) for the entire endograft model were documented in cases K and Ε respectively, while for the main-body, specifically, in cases K and A, respectively.Conclusion : The off – label hybrid AFX – Endurant conbination seem to present theoretically better hemodynamic properties in aneurysms with small infrarenal angulation, where the use of the classic AFX is sufficeint in cliical practice. However, the widened application, of endovascular therapies in challenging and marginal aneurysm anatomies introduces a highly demanding field of reinterventions on the complications of these interventions with off – label hybid solutions combining endografts of different structure, geometry, mecahnical properties and hemodynamic characteristics.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Ioannidis, Georgios
- Ιωαννίδης, Γεώργιος
Subjects
dc:subject × 14- Υπολογιστική μελέτη
- Πολυτομική αξονική αγγειογραφία
- Αορτικό Ενδομόσχευμα
- Κατανόηση Συμπεριφοράς
- Contribution
- Computational studies
- Computed tomography angiography
- Aortic extension
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Κλινική ιατρική, άλλοι τομείς
- Clinical Medicine
- Medical and Health Sciences
- Clinical medicine, miscellaneous
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/51845