dc:descriptionThe success of the clinical practice in contemporary brachytherapy applications depends heavily on the accuracy of the dosimetric data used for the treatment planning, which is an integral part of the whole procedure to maximize the therapeutic benefit. The continuously increasing accuracy in determining the target volume, originating from the developments in medical imaging, has led to the rapid technological progress of brachytherapy techniques, which in turn increased accuracy demands in the dosimetrical treatment planning. As a result, dosimetry using the Monte Carlo simulation method has recently been recognized as the golden standard in contemporary treatment planning for external radiotherapy. For the energy range of brachytherapy however, because of the multiple scattering with low energy transfer to be simulated, the calculation times cannot reach the clinically acceptable levels, so that the Monte Carlo method cannot be introduced in the clinical practice of brachytherapy, particularly for the 192Ir sources that are used in the vast majority of applications. At present, therefore, the treatment planning in brachytherapy is based on look-up tables or precalculated dosimetric data with Monte Carlo simulation for a given source geometry within a homogeneous spherical water phantom of fixed dimensions. These data, superimposed for each source dwell position, give the total dose distribution in each brachytherapy application. But, as the geometry in which these data were calculated departs from the actual geometry of the patient, the whole process ignores the heterogeneous composition of the patient (lung, bone, air, etc.) and the actual patient dimensions as well as any probes used that consist of materials of high atomic number. Results have been reported in the literature highlighting significant errors in clinical brachytherapy dosimetry. In the context of this thesis an effort was made to “modernize” the treatment planning of brachytherapy in the clinical practice, moving from the implant dosimetry that is from its inception, to a truly personalized dosimetric treatment planning that takes into account the actual geometry and inhomogeneities of each patient. Recently, it has been suggested in the literature the use of a method based on solving the linear Boltzman transfer equation for brachytherapy dosimetry. This method is also called “discrete ordinates” method as based on “discretization” of all variables (energy, space, direction) to deterministically define the photon energy flux at each point of an arbitrary geometry. The computational and experimental validation of the performance of this method to achieve clinically acceptable dosimetric accuracy in computational times appropriate for clinical use was the main subject of the thesis, through the use of new commercially available treatment planning system designed for brachytherapy applications, the BrachyvisionTM by Varian Medical Systems. It should be noted that the company incorporated the results of this work to the advanced version of the commercial treatment planning system. As a natural sequence of the above and in an effort to conserve the global uniformity of the clinical practice, a quality control method was proposed for the developing contemporary brachytherapy treatment planning systems, which perform dosimetry calculations based on these advanced dose calculation algorithms. Finally, a method of determining the dosimetric uncertainties due to seed construction parameters was developed and calculations were performed of the broad photon beam transmission factor from monoenergetic data for use in brachytherapy structural shielding applications.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Zourari, Kyveli
- Ζουράρη, Κυβέλη
Subjects
dc:subject × 18- Βραχυθεραπεία
- ΡΑΔΙΕΝΕΡΓΟΝ ΙΡΙΔΙΟΝ 192 (192IR)
- Υψηλός ρυθμός δόσης
- Σχεδιασμός θεραπείας
- Δοσιμετρία
- Υπολογιστική προσομείωση
- Δοσιμετρία με χρήση εικόνων μαγνητικού συντονισμού
- Brachytherapy
- RADIOACTIVE IRIDIUM 192 (192IR)
- HDR
- Radiotherapy treatment planning
- Dosimetry
- Monte Carlo simulation
- MRI dosimetry
- Ιατρική Βιοτεχνολογία
- Ιατρική και Επιστήμες Υγείας
- Medical Biotechnology
- Medical and Health Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/51932