National Technical University of Athens (NTUA)
Συμβολή στην ασφαλή λειτουργία μη διασυνδεδεμένων νησιών με υψηλή διείσδυση ανανεώσιμων πηγών ενέργειας
Abstract
dc:descriptionNon interconnected island power systems (NIIPS) are characterized by high operating costs and restrictions in the renewable energy sources (RES) penetration, despite the high potential that might exist in them. Many island system operators have installed or consider pioneering projects that comprise novel control techniques and energy storage to increase the renewable energy penetration and decrease the operating costs.The present Ph.D thesis focusses on the operational security of non interconnected island systems under high RES penetration levels. Initially, the challenges in the operation of ΝIIPS operating in high RES penetration levels are presented. In addition, the contribution of the inverter based generation in frequency and voltage of NIIPS with high RES penetration is highlighted. In this thesis, a grid forming scheme for the central battery energy storage unit is proposed which can provide voltage control, emulated inertia, fast frequency response service. Its main advantage, compared to a grid following inverter, is that it ensures smooth transition to 100% renewable energy sources penetration. Secondary frequency and voltage control techniques are proposed, as well as an innovative control scheme for automatic generation control based on model predictive control. The different control schemes are evaluated in a Control Hardware in the loop testbed.The new ancillary services by the inverter based generation and the altering operating conditions in the island system require new techniques for the assessment of dynamic security. A novel data driven technique, which is based on the optimal classification trees, is proposed for the extraction of linear rules that predict the system security with high accuracy. This technique is compared with classifiers from other supervised machine learning techniques.The evaluation of data driven classifiers of dynamic security only on a scenarios set might not provide a safe assessment on whether the classifier rules approach accurately all the actual security boundaries. In this PHD dissertation, several cases of data driven classifiers are presented that have with high accuracy on the test set but can not achieve similar levels of accuracy when applied for the calculation of control commands. At the same time, an island system operator would not easily trust a black box classifier with no link to the actual physical representation of the system. Main contribution of this work is the design and application of a novel method that for the first time links a classifier’s performance with a dynamic representation of the frequency dynamics, in the same mathematical formulation, in order to calculate adversarial examples or prove that the data driven classifier rules express a subset of the secure space that is defined by that specific frequency dynamics representations. Through this methodology a secure assessment of the operating conditions according to the dynamic frequency security is guaranteed. Finally, an iterative training procedure is proposed, that leads to classifier rules that guarantee the frequency security, which can be applied in the economic operation of the island.The island’s dynamic security and the impact of the new ancillary services by the inverter based generation should be also taken into account in the economic operation of the system. An innovative formulation of the unit commitment problem is proposed that uses the optimal classification trees rules to force constraints on the frequency dynamic security. To deal with the uncertainty in the system operation, introduce by the RES in their power production and provision of ancillary services, as well as from the system load, a robust optimization formulation is proposed for the day ahead unit commitment problem.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Lagos, Dimitrios
- Λαγός, Δημήτριος
Subjects
dc:subject × 22- Μη διασυνδεδεμένα νησιά
- Ευστάθεια συχνότητας και τάσης
- Επικουρικές υπηρεσίες μονάδων ηλεκτρονικών ισχύος
- Μετατροπέας δημιουργίας δικτύου
- Εκτίμηση δυναμικής ασφάλειας
- Μηχανική μάθηση
- Ασφαλής ημερήσιος προγραμματισμός
- Εύρωστη βελτιστοποίηση
- Non interconnected island systems
- Frequency and voltage stability
- Ancillary services by inverter-based generation
- Grid forming inverter
- Dynamic security assessment
- Machine learning
- Secure unit commitment
- Robust optimization
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Επιστήμες Μηχανικού και Τεχνολογία
- Ηλεκτρική και Ηλεκτρονική μηχανική
- Electrical Engineering, Electronic Engineering, Information Engineering
- Engineering and Technology
- Electrical and Electronic Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/52108