Back to search

Institutes outside Greece

Energy management and control of the thermal environment in bakery premises

Abstract

dc:description

Due to the large concentration of heat releasing equipment over a relatively small area, non air-conditioned bakery shops usually suffer from high temperatures, which exceed comfort temperature levels, especially during the summer. To provide comfortable shop environment for customers and staff an increasing trend is to air condition bakery shops using cassette type heat pump systems. Retailers are also increasingly adopting an open door policy to attract customers through the open doors. Both the use of air conditioning and open doors lead to a substantial increase in energy consumption and greenhouse gas emissions. This project investigates ways of reducing the energy consumption of bakery shops, maintaining at the same time comfortable conditions for the staff and customers.Measurements in real shop environments and in an environmental test chamber have established the energy consumption and heat release from refrigeration and other electrical equipment in the shop. Annual thermal simulations have shown that passive and low energy environmental control options such as mechanical and night-time ventilation have only a small effect on daytime peak shop temperatures. Am effective method of reducing thermal losses through open doors is the use of air curtains to protect the doorway from wind forces. Investigations using an experimentally validated computational fluid dynamics model (CFD) have shown that the critical jet velocity of the air curtain increases with wind velocity. Inclining the air curtain inwards and increasing the jet width provides increased protection of the doorway. The efficiency of a heated air curtain is lower than an ambient air curtain but heating of the curtain air in winter may be desirable for thermal comfort. A correctly designed and installed air curtain will reduce considerably air infiltration through the open doorway and will lead to substantial savings compared to an unprotected door.Uncontrolled operation of heated air curtains and air conditioning systems in shops can lead to considerable energy wastage. This thesis has demonstrated the development of a control system that ensures integration of the performance of the environmental control systems in the shop. Laboratory and on-site monitoring results indicate that the developed control system can provide accurate control of the space temperature and can prevent interactions between the heat pump and air curtain leading to a more than 10% reduction in the environmental impact of the HVAC system in the shops.

Degree

thesis:*
Grantor dc:publisher
Institutes outside Greece
Year dc:date
2002

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Pappas, Theodoros
  • Παππάς, Θεόδωρος

Subjects

dc:subject × 28

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/52137

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Pappas, Theodoros; Παππάς, Θεόδωρος. Energy management and control of the thermal environment in bakery premises. Institutes outside Greece, 2002. http://hdl.handle.net/10442/hedi/52137