National and Kapodistrian University of Athens
Μελέτη ηχωκαρδιογραφικών δεικτών σε ασθενείς με ανεπάρκεια μιτροειδούς που αντιμετωπίστηκαν με διακαθετηριακή επιδιόρθωση (EDGE- to - EDGE repair)
Abstract
dc:descriptionAims: The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodeling in patients with functional mitral regurgitation (FMR) treated with MitraClip.Methods: We retrospectively analyzed 86 high surgical risk patients with severe FMR; of those, 58 were implanted a MitraClip and 28 received medical treatment and served as controls. At baseline and at one-year follow up we performed clinical and echocardiography evaluation to assess global longitudinal strain (GLS) and myocardial work (global work index-GWI, global constructive work-GCW, global wasted work-GWW, global work efficiency-GWE).Results: Mitral regurgitation (MR) was significantly reduced after MitraClip implantation (3.7±0.4 vs 1.7±0.8, p<0.001) and the procedure was associated with improvement in Brain Natriuretic peptide (BNP) levels (980±1027 vs 420±338 pg/ml, p<0.001), New York Heart Association (NYHA) class status (3.2±0.55 vs 2.0±0.6, p<0.001), 6-minute walking test (233±154 vs 286±114m, p=0.01) at follow-up and reduction of left ventricle end-systolic (LVESV) and left ventricle end-diastolic volumes (LVEDV) (152±68 vs 136±43ml, p=0.004 & 219±74 vs 193±66ml, p=0.001, respectively). MitraClip procedure was associated with improvement of LV performance and significant increase of GWI (607±282 vs 650±260mmHg%, p=0.045) and GCW (854±288 vs 949±325mmHg%, p<0.001). Baseline ejection fraction (EF), GLS, GWI, GCW and effective regurgitant orifice area (EROA) were the variables that were associated with reduction of LVEDV one year after intervention (p<0.05 for all) and baseline GCW of the LV was the only variable associated with reduction of LVESV (p=0.002). Receiver operating characteristic curve (ROC) analysis identified that a GLS cut-off value of -8,65% (AUC 0.815, p=0.007) was associated with a 20% reduction of the LVEDV with a sensitivity and specificity of 72% and 70% respectively and that a GCW cut-off value of 846mmHg% (AUC 0.759, p=0.007) was associated with a 10% reduction of LVESV with sensitivity and specificity 79% and 74% respectively. Conclusions: Mitral valve repair with MitraClip has positive clinical and echocardiographic impact in patients with FMR one year after implantation. Preserved GLS and GCW values appear to be associated with LV reverse remodeling post intervention.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Papadopoulos, Konstantinos
- Παπαδόπουλος, Κωνσταντίνος
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/52145