Aristotle University Of Thessaloniki (AUTH)
Η βηματοδότηση στην πρόληψη της κολπικής μαρμαρυγής
Abstract
dc:descriptionThe Pacing for Atrial Fibrillation PreventionSummaryThe ability of pacemaker KM prevention algorithms in patients with tachycardia-bradycardia syndrome (Sick sinus syndrome) who have an indication of DDDR pacemaker implantation has not been fully evaluated. The aim of the present observational study was to determine the pacemaker parameters related to the AF burden and to identify a group of patients with the maximum benefit from the pacing prevention algorithms in terms of symptomatic AF burden improvement. A total of 346 patients (69 ± 5 years old, 215 males) with symptomatic bradycardia and with documented AF episodes (Sick sinus syndrome) were studied. Patients received a DDDR bipolar pacemaker with various AF prevention pacing algorithms. The electrodes were implanted at conventional sites. The follow-up was done every 6 months for 36 months. The parameters evaluated were: the total number of AF episodes, the total time spent in AF, the maximum duration of AF episodes, the average duration of AF episodes, the PACs burden and the atrial and ventricular pacing percentage. The study showed a statistically significant reduction in the maximum and mean duration of AF episodes in the first 18 months (ANOVA P <0.01). At the same time, there was a reduction of the symptomatic AF burden and a reduction in morbidity, the need for hospitalization and an improvement in the quality of life of these patients. The total number of AF episodes, the total time spent in AF and the PACs burden did not show a significant change during the follow-up. Significant variation in treatment response was observed between patients (inter-individual variability) and at the same patient during follow-up (intra-individual variability), it is necessary the evaluation and, if needed, the reprogramming of the device parameters every 6 months. AF prevention pacing algorithms have a large response variation and have a relatively short-term benefit that mainly concerns certain features of AF episodes, without affecting the total AF burden. Due to the complexity of the AF mechanisms and the large variations in the response to the prevention pacing algorithms, even in the same patient, regular monitoring and analysis of parameters and their appropriate adjustment are necessary to maximize the benefit of this therapy. The conclusions of this study are applicable to the new generation devices with AF prevention pacing algorithms.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Thomaidi-Danasel, Adina
- Θωμαΐδη-Ντανασέλ, Αντίνα
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/52398