University of Ioannina
Ιατροδιαγνωστικές φορητές συσκευές βασισμένες σε καινοτόμους βιοαισθητήρες αποκρινόμενων πολυμερικών μεμβρανών και μεταλλάκτες χαμηλού κόστους για χρήση στο σημείο περίθαλψης
Abstract
dc:descriptionThe development of medical diagnostic devices for point-of-care applications (PoC) is a key demand towards the establishment of decentralized health-care systems. The cost of miniaturized transducers, the need for elaborated modification of the sensing surface and the complexity of the assay workflow impede the widespread use of current biosensing technologies to PoC applications. In the first section, is described the development of a portable medical diagnostic device (we call it “BioPoC”), which employs free-standing enzyme-modified responsive polymer membrane-based biosensors and a newly devised low-cost transduction principle. The device includes a single vertical channel with an integrated sample dosing well. Its operation is based on the measurement of the time required the originally infinite electric resistance between two, separated by the enzyme-modified responsive polymer membrane, conductive strips to reach a finite value as a result of the target-triggered degradation of the polymer membrane and the ensuing vertical flow of the sample, which thus establishes an electrical communication between the conductive strips. The time is proportional to the concentration of the target. As part of the proof-of-concept, BioPoC device was employed for the determination of urea in undiluted human urine. By proper selection of the membrane thickness and concentration of copolymer, device operation was adjusted to the analyte concentration range in urine. Data demonstrate an outstanding selectivity against the components of the matrix, while the detection range can be tuned over the normal range of the analyte of interest.In the second section, a SIM card-type pH responsive polymer-modified paper-based biosensing device, coupled to a smartphone, for the determination of urinary creatinine was developed. A vertical microfluidic channel was fabricated on a paper strip by wax printing. The hydrophilic area was coated by a poly(methylmethacrylate)/ poly(methacrylic acid) random copolymer, PMMA-co-PMAA, and on top of it, creatinine deiminase (CD) was immobilized. Data demonstrated, on the one hand, zero vertical flow of urine through the enzyme-free PMMA-co-PMAA-modified paper strip, i.e., a high selectivity against the components of the matrix, and on the other hand, in the presence of CD, a creatinine -concentration dependent commence of sample’s downward flow due to the selective, creatinine-triggered degradation of the copolymer by the enzymatically produced ammonia. This CD/ PMMA-co-PMAA paper-based biosensing smart assembly is coupled with three conductive strips, which enable the automatic on/off (sample addition/measurement end) measurement of the copolymer degradation time, through electric resistance measurements. It also features an in-built sample well and wireless communication support through the integration of a Bluetooth® microprocessor incorporated with time and resistance measuring circuits. Using newly synthesized pH responsive PMMA-co-PMAA at different molecular weights and volume fraction ratios offering tunable dissolution properties, the detection range was adjusted over 3–30 mM creatinine to overspread the normal range of creatinine in urine. The device was successfully applied to the determination of urinary creatinine.In the last section, the development of a sensor for the detection of Helicobacter pylori, by applying the BioPoC technology, is described. Utilizing the enzyme urease produced by this bacterium, a sensor that responds to pH changes, in the presence of urea solution was developed. Various pH-responsive copolymers were examined to develop a sensitive sensor that would enable the detection H. Pylori, even at the early stages of infection. The examination of bioptic samples was performed at the patient's point of examination, providing results in less than 30 minutes. The results were comparable to those obtained by a commercial test (CLO) and the histologic examination. The specificity and the sensitivity of the BioPoC sensor were found to be 92% and 83%, respectively.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tzianni, Eleni
- Τζιάννη, Ελένη
Subjects
dc:subject × 34- Βιοαισθητήρες
- Αποκρινόμενα πολυμερή
- Πολυμερικές μεμβράνες
- Aπόκριση στο pH
- Ουρία
- Κρεατινίνη
- Ελικοβακτηρίδιο πυλωρού
- Χρωματογραφικό χαρτί
- Ιατροδιαγνωστική συσκευή
- Σημείο περίθαλψης
- Ένζυμα
- Αναλυτική συσκευή
- Μέτρηση χρόνου
- Μέτρηση αντίστασης
- Biosensors
- Stimuli responsive polymers
- Polymer membranes
- pH responsive polymers
- Urea
- Creatinine
- Helicobacter pylori
- Chromatography paper
- Medical diagnostic device
- Point-of-Care
- Enzymes
- Analytical device
- Measurement of time
- Measurement of resistance
- Χημεία
- Φυσικές Επιστήμες
- Αναλυτική χημεία
- Chemical Sciences
- Natural Sciences
- Analytical Chemistry
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier