National and Kapodistrian University of Athens
Παράμετροι θρομβοελαστομετρίας για την εκτίμηση της πρωτογενούς αιμόστασης στα νεογνά
Abstract
dc:descriptionBackground: Ill preterm and full-term neonates present increased risk of hemorrhage, with a negative impact on outcome and survival. As bleeding in this setting is multifactorial, an index incorporating both platelet count and functionality to more accurately depict neonatal hemostatic status, would be ideal.Aim: Our aim was to investigate the potential role of certain thromboelastometry (ROTEM) parameters, including maximum clot elasticity (MCE) and platelet component (PLTEM MCE and PLTEM MCF) in early prediction of bleeding events in thrombocytopenic critically ill neonates. Material and methods: This single-centre, prospective, cohort study included 110 consecutive thrombocytopenic neonates with sepsis, suspected sepsis or perinatal hypoxia. On the first day of sepsis or suspected sepsis and/or hypoxia, along with the appropriate workup, the ROTEM EXTEM and FIBTEM assays were conducted on arterial blood samples. The neonatal bleeding assessment tool (NeoBAT) was used for the evaluation of bleeding events on the same day with ROTEM analysis. Results: Most EXTEM and FIBTEM ROTEM parameters significantly differed between neonates with (n = 77) and without bleeding events (n = 33). Neonates with bleeding events had significantly lower PLTEM MCE and PLTEM MCF values compared to those without bleeding events (p <0.001). Platelet count was found to be strongly positively correlated with EXTEM A10 (Spearman rho = 0.64, p <0.001) and EXTEM A5 (rho = 0.61, p <0.001), while a weak positive correlation was shown with EXTEM MCF (rho = 0.40, p <0.001), EXTEM MCE (rho = 0.38, p <0.001), PLTEM MCF (rho = 0.33, p = 0.001) and PLTEM MCE (rho = 0.29, p = 0.004). Adjusted evaluation of the correlation between ROTEM parameters and hemorrhage revealedthat only EXTEM A10 (OR = 0.88, 95% CI:0.81 – 0.95, p = 0.003), PLTEM ΜCE (OR = 0.90, 95% CI:0.82 –0.99, p=0.043) and PLTEM MCF (OR = 0.96, 95% CI:0.92 – 0.99, p=0.039) were significantly correlated with bleeding, while FIBTEM A10 was not associated with hemorrhage (aOR = 0.94, 95% CI 0.87 – 1.02, p = 0.16). EXTEM A10 demonstrated the best prognostic performance (AUC = 0.853) with an optimal cutoffvalue of ≤37mm (sensitivity = 91%, specificity = 76%) for prediction of bleeding events in thrombocytopenic neonates. Similar results emerged for EXTEM A5 (AUC = 0.850) with an optimal cut-off value of ≤28mm (sensitivity = 91%, specificity = 77%). Conclusions: EXTEM A10 and EXTEM A5 parameters were found to be strong predictors of hemorrhage, compared to most ROTEM variables quantifying clot elasticity or platelet component in thrombocytopenic, critically ill neonates.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Parastatidou, Stavroula
- Παραστατίδου, Σταυρούλα
Subjects
dc:subject × 20- Θρομβοελαστομετρία
- Νεογνά
- Αιμόσταση
- Θρομβοπενία
- Αιμοπετάλια
- Αιμορραγία
- Thromboelastometry
- Neonates
- Hemostasis
- Thrombocytopenia
- Platelets
- Hemorrhage
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Παιδιατρική, Νεογνολογία και Υγεία του παιδιού
- Αιματολογία
- Clinical Medicine
- Medical and Health Sciences
- Pediatrics, Perinatology and Child Health
- Hematology
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/53664