Back to search

Aristotle University Of Thessaloniki (AUTH)

Διερεύνηση της κρουστικής εκκένωσης κορώνα σε εναέριες γραμμές μεταφοράς

Abstract

dc:description

Surge corona characteristics on overhead transmission lines are investigated. Using computational models that consider the ionization processes in corona discharge, the corona inception field of conductors typically utilized in overhead transmission lines is estimated. The interactive effects of line conductor geometry, voltage polarity as well as atmospheric conditions on corona inception field are assessed and discussed based on the ionization area around the conductor. An empirical model for the straightforward estimation of the corona inception field of line conductors is introduced, accounting well for the effects of conductor geometry, voltage polarity and atmospheric conditions. The proposed model is a useful tool for designing overhead transmission lines, allowing for the evaluation of corona activity as well as for the estimation of the surface irregularity factor of line conductors in service. Corona characteristics under steady or slowly varying electric fields should not extend to the case of surge corona. Thus, inception and growth characteristics of surge corona on cylindrical conductors, as affected by the spatial and temporal variations of the electric field, as well as atmospheric conditions, are investigated. Surge corona on line conductors may initiate and grow in various modes, namely glow, intermittent or stable streamer discharge. These modes are associated with different temporal variations of growth characteristics, critically dependent on the wavefront steepness of the electric field stress. Based on experimental data, a model for estimating surge corona inception and growth characteristics is introduced. The proposed model can be easily implemented in surge studies for the estimation of the attenuation and distortion of overvoltage surges propagating on overhead transmission lines. In transient studies, neglecting corona effects on surges propagating along line conductors and incoming to the connected substations may result in over-designed insulation systems and means for overvoltage protection. Thus, knowledge of surge corona characteristics is essential for improving the design of insulation systems and reliability of power systems.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Bousiou, Evanthia
  • Μπούσιου, Ευανθία

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/53688

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Bousiou, Evanthia; Μπούσιου, Ευανθία. Διερεύνηση της κρουστικής εκκένωσης κορώνα σε εναέριες γραμμές μεταφοράς. Aristotle University Of Thessaloniki (AUTH), 2022. http://hdl.handle.net/10442/hedi/53688