Back to search

National Technical University of Athens (NTUA)

Βελτιστοποίηση της διαχείρισης υδατικών πόρων - ενέργειας σε νησιά με τεχνικές μαθηματικής προσομοίωσης

Abstract

dc:description

Contribution of Renewable Energy Sources’ (RES) power generation in the energy mix of Non-Interconnected Island Systems (NIIs) remains limited, which prevents the vast exploitation locally of both environmental and economic benefits accruing from its extensive use. The problem of limited RES contribution may be addressed by means of different flexibility options, including energy storage, interconnections and demand side management. Through the conduction of a comprehensive literature review and the collection of recent data for the NIIs of the Aegean Sea, the following may be noted. 1. Annual RES shares appear to be low, kept in the order of ~15%. 2. Local energy needs are mainly covered by the use of fossil fuels, rather than by means of exploiting the local wind and solar energy potential. 3. Ιn NIIs of large scale, wind parks demonstrate low values of annual capacity factors, between 22% and 28%. This is due to the occurrence of wind energy curtailments, resulting from the need to maintain grid stability on the one hand, and the limited flexibility of the local electricity systems on the other. Ιn certain NIIs, wind energy curtailments may even reach 30% of the respective theoretical wind energy production on an annual basis, which is also the case for the examined system of Kos and Kalymnos. Integrated management of energy and water systems may contribute to the recovery of wind energy curtailments. To that end, an Intelligent Management System (IMS) / decision making tool has been developed under the current thesis, comprising of three different optimization models. The latter include: 1. The Energy System Optimization Model (ESOM): The ESOM solves the problem of energy balance and unit commitment for the examined electricity system, including thermal units, PV stations, wind parks as well as a battery-based hybrid power station and applies an objective function that minimizes the system operational costs. 2. The Water System Optimization Model (WSOM): The WSOM solves the problem of water balance and pump scheduling for the examined water system and applies an objective function that minimizes the integrated energy consumption of pumps. 3. The Water & Energy Systems’ Optimization Model (WESOM): The WESOM combines the previous two optimization model and synthesizes them in an integrated optimization model. The latter optimizes the management of the water and energy systems when coupled, allowing for the application of demand side management strategies with the use of a set of pumps. Under the WESOM, the problems of economic dispatch and unit commitment, as well as the problem of pumps’ scheduling are solved simultaneously. Development of the prototype IMS stands as the main outcome of the given thesis. The latter takes the form of an integrated, sophisticated simulation software and platform that also supports the incorporation of ML-based prognostic models and/or synergy with external forecasting services. Above all, the IMS serves the purpose of effective planning and optimum operation of energy and water systems. It does so by facilitating the elaboration of different scenarios and strategies together with the assessment of benefits deriving from the integrated management of water and energy systems in the Greek NIIs. For the test-application of the IMS, the NII system of Kos-Kalymnos and the water system of Tilos (Livadia) were used, with all three optimization models exercised and with the main conclusions obtained laid down in the following: 1. From the energy system point of view, the main benefit generated by the exercise of the integrated water and energy management concerns the increase of RES shares (wind parks and hybrid power station), at the expense of thermal power generation, leading also to the reduction of the system operational costs. As far as increased RES shares are concerned, they derive from the recovery of otherwise curtailed wind energy, which should also normally come at a lower cost. 2. From the water system point of view, both lower operational costs and higher RES coverage of the respective energy consumption were achieved for the examined fleet of water pumps, enabled by the practice of load shifting under a strict set of operational constraints. 3. Following from the above, it can be argued that even in the context of a rather constrained test-case currently examined, the IMS proved its potential to serve the goal of operational costs’ minimization at system level, while at the same time achieving optimized asset management at the water system side. This is indicative of results anticipated in the case of more flexible assets, such as with inverter-driven water pumps, or portfolios of different assets.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Tzanes, George
  • Τζάνες, Γεώργιος

Subjects

dc:subject × 24

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/54235

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Tzanes, George; Τζάνες, Γεώργιος. Βελτιστοποίηση της διαχείρισης υδατικών πόρων - ενέργειας σε νησιά με τεχνικές μαθηματικής προσομοίωσης. National Technical University of Athens (NTUA), 2022. http://hdl.handle.net/10442/hedi/54235