Back to search

National and Kapodistrian University of Athens

Μελέτη ασφάλειας της προδιάτασης με μπαλόνι μεταξύ αυτό-εκπτυσσόμενων βαλβίδων σε ασθενείς που υποβάλλονται σε TAVI

Abstract

dc:description

Background: Pre-dilatation in Transcatheter Aortic Valve Implantation (TAVI) is still a controversial topic and clinical data investigating this issue are limited. This study aimed to evaluate the impact of balloon pre-dilatation between self-expanding valves. Methods: In this prospective, multicenter, non-randomized clinical trial 78 patients were consecutively recruited and received ACURATE neo valve. This group was compared with two groups of CoreValve/ Evolut R/PRO receivers (85 without and 86 with balloon pre-dilatation) from the DIRECT study. The primary endpoint was device success according to VARC-2 criteria. Results: VARC-2 device success for the three groups was 87.2% vs 76.5% vs 74.4% (p=0.10). VARC-1 rates were 91% vs 88.2% vs 87.2% (p=0.73) and VARC-3 87.2 vs 92.9% vs 91.9% (p=0.41) respectively. 1 death occurred in the ACURATE neo and no death in the CoreValve/Evolut groups. Permanent pacemaker implantations (PPI) (3.8 vs 22.4% vs 25.9%, p<0.001) and ≥moderate prosthesis-patient mismatch (PPM) (3.8 vs 21.2 vs 20.9, p=0.002) after TAVI were significantly lower with the ACURATE neo valve. Post-dilatation was more frequent in the ACURATE neo group (33.3 vs 29.4 vs 15.1%, p=0.018). Conclusions: ACURATE neo demonstrated similar device success rates according to all VARC criteria, comparable to the CoreValve/Evolut valves and exhibited lower rates of new PPI and PPM. Despite ACURATE neo was implanted with pre-dilatation, post-dilatation was more frequently required. The lowest rate of post-dilatation was observed in patients that underwent pre-dilatation and received CoreValve/Evolut valves.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Koliastasis, Leonidas
  • Κολιαστάσης, Λεωνίδας

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/54577

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Koliastasis, Leonidas; Κολιαστάσης, Λεωνίδας. Μελέτη ασφάλειας της προδιάτασης με μπαλόνι μεταξύ αυτό-εκπτυσσόμενων βαλβίδων σε ασθενείς που υποβάλλονται σε TAVI. National and Kapodistrian University of Athens, 2023. http://hdl.handle.net/10442/hedi/54577