Back to search

Democritus University of Thrace (DUTH)

Ακτινική επιβάρυνση από ακτινογράφηση και υπολογιστική τομογραφία κωνικής δέσμης στην απεικονιστικά καθοδηγούμενη ακτινοθεραπευτική πράξη

Abstract

dc:description

The application of modern techniques for delivering high therapeutic dose from X-ray provided by a linear accelerator (LE) requires strict and repeatable spatial precision. This happens in order for the target tumor to receive the calculated dose with a simultaneous reduction of the radiation burden of the neighboring healthy organs and a reduction of unwanted side effects. The control of the accuracy of patient's treatment position in the radiotherapy table, as well as the confirmation of the target tumor, are achieved by using radiological imaging systems adapted to Linac. Irradiation parameters (kVp, mA, mSec) and irradiation conditions may vary widely, having direct effect on the corresponding range of absorbed doses by patient's organs. In addition, theoretical radiogenic risk from OBI depends, among other factors, on the type of imaging (2D x-ray, or 3D cone beam computed tomography / CBCT) and on the total number of scans until the completion of the treatment. Considering that every appliance of ionizing radiation must be optimized to the maximum extent possible, this PhD thesis aims to ensure the right operation and control of OBI imaging systems, quantify the risk through the estimation of the absorbed organ dose and propose minimization methods of. In the preliminary study, somatometric and demographic data of 512 patients who underwent imaging-guided radiation therapy were collected, as well as the exposure data of the imaging procedures. Commercially available PCXMC software was used to calculate organ absorbed doses and patient effective doses from radiographs, while the newest version of the PCXMC 2.0 software was used for the corresponding calculations of doses from CBCT cone beam tomography. Specifically, for CBCT scans, two different simulation models of the half & full fan bowtie filters were developed whose results show strong correlation between them and in the experimental results. Thorough calculations were performed for assumptions of different imaging isocenter positions, acquisition angles, and patient BMIs. Moreover, special attention was given to experimental determination of eye lens doses for different scanning conditions. As far as X-rays are concerned, in the present study a methodology was developed, and the protocols were optimized for the head/neck and pelvis regions, thus achieving a significant reduction in the absorbed doses. The optimized protocols were incorporated into the clinical routine after pilot appliance and outcome evaluation. Finally, the experimental part of the study includes a methodology with the use of three dosimetric tools a) thermoluminescence dosimeters TLD-100 b) Gafchromic XR-QA2 radiochromic films and c) Sun Nuclear IVD diodes. Dosimetric tools were calibrated for the radiographic system studied and their individual physical and technical characteristics (accuracy, repeatability, energy dependence, etc.) were investigated.

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Velonis, Marios
  • Βελώνης, Μάριος

Subjects

dc:subject × 15

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/55242

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Velonis, Marios; Βελώνης, Μάριος. Ακτινική επιβάρυνση από ακτινογράφηση και υπολογιστική τομογραφία κωνικής δέσμης στην απεικονιστικά καθοδηγούμενη ακτινοθεραπευτική πράξη. Democritus University of Thrace (DUTH), 2023. http://hdl.handle.net/10442/hedi/55242