University of Ioannina
Ανάπτυξη και εφαρμογές αναλυτικών μεθόδων για τον προσδιορισμό ξενοβιοτικών ενώσεων σε ζωικούς και φυτικούς οργανισμούς θαλάσσιων οικοσυστημάτων: εκτίμηση επικινδυνότητας
Abstract
dc:descriptionOne of the major issues of recent years is the control of the residuality of organic pollutants in various environmental substrates, which necessitates the development of reliable analytical methods for their detection. In recent years, the number of studies dealing with the development and application of analytical methods to estimate the concentration levels and fate of such xenobiotic compounds in the environment is constantly increasing. Most of these studies deal mainly with surface water and soil, but there is a lack of data on aquatic ecosystems, as well as on the organisms that live in them. In this Thesis, analytical methods were developed and validated for the determination of 14 selected polychlorinated biphenyls (PCBs) and 4 nitrofuran metabolites in fish and seafood samples. The methods were finally applied in areas of Greece and Portugal, where, apart from other man-made activities, aquaculture also operates. Criteria for the selection of the compounds were their constant presence in the environment, including compounds whose use has been banned but are still detected. A Gas Chromatography system coupled with Mass Spectrometry (GC-MS) was used for the determination of PCBs with a total analysis time of 30 minutes. A liquid chromatography system coupled with high resolution mass spectrometry was used for the determination of nitrofuran metabolites, with a total analysis time of ten minutes. Matrix match calibration curves and in the case of nitrofuran metabolites also an internal standard was used for the quantification on the selected compounds. For the determination of PCBs in fish and seafood samples, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) extraction method was chosen. To determine the optimal extraction conditions, the extraction solvent, the extraction salts, the amount of the sample and different combinations of adsorbents were studied for the clean-up step. After optimization, validation of the analytical methodology followed for each substrate. In mussel samples the recoveries ranged from 72.5% to 109.5%, while the standard deviation was less than 10%. In fish samples, recoveries ranged from 72.1% to 85.0%, while repeatability and intra-laboratory reproducibility were less than 10%. Regarding the limits of quantification, they were less than 2.5 ng g-1 for all PCBs on both substrates. Furthermore, values of matrix effect were found to vary for mussel samples between -28.9% and 22.0% indicating a moderate to slight effect and for fish samples between -17.8% and 16.0% indicating a slight effect. The last stage for the validation of the analytical methodology was the estimation of the uncertainty of the method, where it was found for all PCBs at values below 53% on both substrates. Subsequently, the validation was extended for the remaining organisms under study at the low fortification level, with the analytical characteristics of the method making it suitable for these substrates as well. Finally, the coefficient of linearity was above 0.99 in all cases. After the validation of the method, application to real fish and seafood samples from one region in Greece and one in Portugal followed. In the samples collected from the Greek region, none of the selected PCBs were found above the detection limit. On the contrary, in the area of Tagus River, PCBs were detected and quantified in crab, seaweed and mussel samples. Two sampling campaigns conducted in the same year, one after a rainy season and one after a dry season, and in the second season, the positive detections of PCBs were more in number and in higher concentrations. For the determination of nitrofuran metabolites in fish tissue samples, liquid-liquid extraction was chosen after digestion of the sample, which is also the main method used for these analytes. Recoveries ranged from 85.2% to 98.4%, while repeatability and intra-laboratory reproducibility were less than 10%. Regarding the limits of detection (LOD) and quantification (LOQ) they were calculated at 0.1 ng g-1 and 0.25 ng g-1 respectively. The last stage for the validation of the analytical methodology was the estimation of the uncertainty of the method, where it was found at values below 50% for all metabolites. The validated methodology was applied to fish samples from a Mediterranean aquaculture over a period of four years. Among the four metabolites, the metabolite Amoz was detected in a large number of samples but only in the first year of the sampling. The concentrations ranged from the quantification level of the method, up to 3.96 ng g-1, with the Reference Point for Action (RPA) being 1.0 ng g-1. All actions required by the legislation were taken by the fish farm, with the result that in the following months Amoz concentrations gradually decreased and finally came to values below the detection limit of the method. Finally, a chronic dietary risk assessment was performed for both selected groups of compounds. Regarding the risk from polychlorinated biphenyls, Hazard Index (HI) did not exceed 0.25, confirming that the risk from seafood consumption remains low for each individual food. For nitrofuran metabolites, there is no specific acceptable consumption limit, as the legislation is strict and taking all the necessary actions, the risk to the consumer remains minimal.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Trantopoulos, Epameinondas
- Τραντόπουλος, Επαμεινώνδας
Subjects
dc:subject × 18- Ξενοβιοτικές ουσίες
- Υδρόβιοι οργανισμοί
- Αναλυτικές μέθοδοι
- Αέρια χρωματογραφία
- Υγρή χρωματογραφία
- Εκτίμηση επικινδυνότητας
- Xenobiotics
- Marine ecosystem
- Analytical methods
- GC-MS
- LC-MS / MS
- Risk assessment
- Χημεία
- Φυσικές Επιστήμες
- Χημεία, άλλοι τομείς
- Chemical Sciences
- Natural Sciences
- Chemistry, miscellaneous
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/55350