Democritus University of Thrace (DUTH)
Αξιολόγηση του ρόλου της αυτοματοποιημένης αρτηριακής πίεσης ιατρείου (AOBP) ως προγνωστικού παράγοντα σε ασθενείς με χρόνια νεφρική νόσο (ΧΝΝ) και υπέρταση
Abstract
dc:descriptionIntroduction: Chronic kidney disease (CKD) is a global issue of public health. Despite the prevalent use of interventions to delay CKD progression, the prevalence of end-stage kidney disease (ESKD) in many industrialized nations continues to rise. It has been reported that between 85% and 95% of patients with CKD (stages 3–5) experience hypertension. Hypertension is the most significant modifiable risk factor for CKD progression and the primary risk factor for mortality in CKD patients. As a result, appropriate evaluation and management of hypertension to achieve BP targets in patients with CKD can delay the progression of CKD and decrease the elevated risk of cardiovascular (CV) disease. Similarly to the general population, the diagnosis of hypertension among individuals with CKD is based on office blood pressure measurements (OBP) and, in the past few decades, ambulatory blood pressure measurements (ABPM). The last method appears to be more accurate, not only in detecting hypertension but also in predicting the risk of cardiovascular disease, although its high cost limits its widespread application. Automated office blood pressure monitoring (AOBP) has been proposed to enhance the accuracy of office blood pressure (OBP) readings. AOBP simply requires that readings be obtained with a fully automated oscillometric sphygmomanometer that records multiple blood pressure (BP) measurements with the patient sitting alone and in a calm environment. Numerous comparative studies in non-CKD patients have demonstrated that AOBP correlates better than manual OBP with left ventricular mass and microalbuminuria in hypertensive patients and with intima-media thickness of the carotid artery in normotensive volunteers; this correlation is comparable to that of ABPM. In a study of hypertensive patients with CKD, routine OBP readings were substantially higher than AOBP readings, but there was no significant difference between AOBP readings and 24h ABPM in this setting. However, information regarding the prognostic value of AOBP readings in hypertensive patients with CKD is still lacking. Purpose: The primary objective of this PhD thesis is to investigate the role of AOBP as a prognostic factor for CV and renal outcomes in patients with hypertension and CKD stage 3-5 not on dialysis. The secondary objective is to compare the BP values with the three methods of BP measuring, OBP, AOBP and daytime ABPM in the same patient population. Methods: At baseline,140 patients who met the inclusion criteria were recruited and BP measurements with three different methods, OBP, AOBP and ABPM were recorded. The measurements of the BP were carried out in the following order. On the first day in the morning 8.30-10.30, OBP was obtained with the presence of a doctor and then, was placed on the patient the BP Holter device for the ABPM. The next day in the morning the BP Holter device was removed, and the patient was led to a quiet room where the AOBP recordings were carried out without the presence of medical and nursing staff. The patients were prospectively monitored for a median period of 3.4 years. During the follow-up, information on the control of BP, antihypertensive treatment and the occurrence of any CV and renal events was evaluated. The primary outcome of this study was a composite outcome of CV events or doubling of base line serum creatinine or progression to ESKD, whichever occurred first. CV events included fatal or non-fatal CV events: myocardial infarction, diagnosis of coronary heart disease, coronary revascularization, hospitalization for heart failure, stroke and intermittent claudication-interventions for peripheral arterial disease. Results: At baseline, the median age of patients was 65.2 years, 36.4% were diabetics, 21.4% had a history of CV disease, the mean eGFR was 33mL/min/1.73 m2, and the mean of systolic and diastolic OBP, AOBP and daytime ABPM were 151/84 mmHg, 134/77 mmHg and 132/77 mmHg respectively. Using the student’s t-test (paired samples) it emerged that the AOBP measurements were statistically significantly lower than the OBP measurements while they did not show any significant difference with the daytime ABPM. During follow-up, 18 patients experienced a CV event and 37 patients had a renal event. In the univariate Cox regression analysis systolic AOBP readings found to be predictive of the primary outcome (HR for every 1 mmHg increase in BP: 1.019, 95% CI: 1.003–1.035) while on the contrary, diastolic AOBP did not seem to have any predictive value. However, applying the multivariate model, systolic and diastolic AOBP readings proved to be both prognostic in terms of the composite endpoint (HR for every 1 mmHg increase in BP: 1.017, 95% CI: 1.002–1.032 and HR for every 1 mmHg increase in BP: 1.033, 95% CI: 1.009–1.058 respectively). Systolic and diastolic OBP readings could not predict any outcome meanwhile diastolic OBP readings using the adjusted model found to be predictive (HR for every 1 mmHg increase in BP: 1.026, 95% CI: 1.003-1.049). Regarding the systolic daytime, nighttime and 24hr ABPM, applying the unadjusted model, it seemed to be predictive of occurrence of the composite endpoint (HR for every 1 mmHg increase of BP: 1.024, 95% CI: 1.007-1.040, HR for every 1 mmHg increase in BP: 1.031, 95% CI: 1.016-1.046 and HR for every 1 mmHg increase in BP: 1.030, 95% CI: 1.014–1.047 respectively) while on the contrary, diastolic daytime, nighttime and 24hr ABPM did not appear to have any predictive value. However, applying the adjusted model, systolic daytime ABPM was marginally non-predictive while a significant correlation was shown between systolic nighttime and 24hr ABPM with the composite endpoint of the study (HR for every 1 mmHg increase in BP: 1.024, 95% CI: 1.009-1.039 and HR for every 1 mmHg increase in BP: 1.022, 95% CI: 1.006-1.039 respectively). Finally, according to the adjusted model, diastolic daytime-nighttime and 24hr ABPM was predictive of the primary endpoint (HR for every 1 mmHg increase in BP: 1.033, 95% CI: 1.004-1.063, HR for each 1 mmHg increase in BP: 1.041, 95% CI: 1.013-1.069 and HR for every 1 mmHg increase of BP: 1.0 42.95% CI: 1.012-1.073 respectively).Conclusions: In the present PhD thesis, it has been attempted to compare three methods of BP measurement (OBP, AOBP, and daytime ABPM) and to investigate the predictive value of AOBP in hypertensive patients with CKD stages 3-5 who were not on dialysis. Systolic and diastolic AOBP measurements were substantially lower than those of OBP but comparable to those of daytime ABPM, according to the study's findings. Analysis of the predictive value of AOBP revealed that elevated systolic and diastolic AOBP measurements were associated with poor CV and renal outcomes. The results above enhance the position of AOBP in clinical practice as a reference method of BP measurement for the evaluation of BP in the clinic in patients with hypertensive CKD stages 3-5 who are not on dialysis. In conclusion, the findings of the present study entirely support the decision of the KDIGO 2021 Clinical Practice Guideline for the Management of Blood Pressure in Chronic Kidney Disease to recommend AOBP as the optimal method for measuring BP in the clinic.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Psounis, Konstantinos
- Ψούνης, Κωνσταντίνος
Subjects
dc:subject × 20- Αυτοματοποιημένη αρτηριακή πίεση ιατρείου
- Χρόνια νεφρική νόσος
- Υπέρταση
- Καρδιαγγειακά συμβάματα
- Νεφρικά συμβάματα
- Automated office blood pressure
- Chronic kidney disease
- Hypertension
- Cardiovascular events
- Renal events
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Νεφρολογία
- Επιστήμες Υγείας
- Επιστήμες υγείας, άλλοι τομείς
- Clinical Medicine
- Medical and Health Sciences
- Nephrology
- Health Sciences
- Health sciences, miscellaneous
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/55410