Back to search

Institutes outside Greece

The effect of experimental and modeling parameters on combined EEG/MEG source analysis and transcranial electric stimulation optimization of somatosensory and epilepsy activity

Abstract

dc:description

New experimental and modeling parameters are introduced to investigate effects on combined electroencephalography (EEG) and magnetoencephalography (MEG) – EMEG source analysis and transcranial electric stimulation (TES) optimization of somatosensory evoked and epileptic activity. Simultaneous data are measured, including somatosensory evoked potentials (SEP) and fields (SEF) elicited by different stimulation types for group-based sensitivity investigations and spontaneous EEG and MEG measures for presurgical epilepsy diagnosis. Individualized finite element head volume conductor models are constructed in the solution of the forward problem of source analysis. For this purpose, a quasi-automatic image processing procedure is introduced, combining T1-weighted and T2-weighted MRIs. For realistic modeling of the conductive properties of brain, diffusion tensor imaging is used. Skull conductivity is individually calibrated due to its high inter-subject variability and influence on EEG and EMEG source reconstructions. It is also presented how different stimulation types, head models and measurement modalities (EEG, MEG or EMEG) influence the source reconstruction of SEP/SEF response at 20 ms post-stimulus (P20/N20) and the targeting in multi-channel TES optimization. Inter-subject variability of skull conductivity and thickness over age are investigated non-invasively. Finally, EMEG source analysis with realistic head models that include skull burr holes are evaluated for the presurgical diagnosis of a drug-resistant epilepsy patient. Optimized TES is investigated as an alternative of surgery to suppress epileptic seizures. Results show that MEG stabilizes the P20/N20 location and EEG contributes to the determination of the source orientation. The complementarity of both modalities in EMEG can be utilized on the basis of detailed and individualized head models. Subsequently, optimized TES electrode montages are reported to be affected by the P20/N20 orientation component. For head modeling, it is presented that the inter-subject variability of conductivity and thickness of skull is large and it should be taken into account in source analysis and TES. In this regard, subjects' age and skull thickness are significantly related to the skull conductivity. For presurgical epilepsy evaluation, EMEG source analysis with calibrated and anisotropic head models indicates a focal cortical dysplasia (FCD) at the onset of the epileptic spike peak. Simplified head models, use of single modality or time points close to the spike peak cause non-negligible influences on the determination of the FCD. Finally, changes on the head modeling reflect considerable influences on the optimized TES and the flow of the injected direct currents towards the FCD.

Degree

thesis:*
Grantor dc:publisher
Institutes outside Greece
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Antonakakis, Marios
  • Αντωνακάκης, Μάριος

Subjects

dc:subject × 21

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/55726

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Antonakakis, Marios; Αντωνακάκης, Μάριος. The effect of experimental and modeling parameters on combined EEG/MEG source analysis and transcranial electric stimulation optimization of somatosensory and epilepsy activity. Institutes outside Greece, 2021. http://hdl.handle.net/10442/hedi/55726