Back to search

University of the Aegean

Study on the performance of constructed wetlands planted with ornamental plants for on-site greywater treatment in urban areas

Abstract

dc:description

Urbanization, population growth, and climate change are contributing to an increase in water scarcity problems. The search for alternative water sources for non-potable use, such as greywater treatment, is a one-way solution. Among the different types of systems that are being used for greywater treatment, nature-based solutions and more specifically, constructed wetlands are drawing the attention due to the low energy and maintenance requirements. Among the various types of constructed wetlands, vertical flow constructed wetlands from the subsurface flow category, are being used at great rate due to the greater oxygen transfer capacity resulting in enhanced biodegradation and nitrification. Moreover, floating treatment wetlands from the free surface category have started drawing attention over the last decade as an economic water purification method, especially in eutrophic lakes. Among the characteristics that play a key role in constructed wetlands’ operation are substrate and vegetation. Regarding substrate selection in vertical flow constructed wetlands, sand and gravel are the ones that are mostly selected due to their availability and low cost. In floating treatment wetlands there is a wide range of buoyant materials the choice of whom determine systems durability and effectiveness as well as the enhancement of sedimentation. The plant species that are usually chosen in CWs are species of Phragmites, Scirpus, Typha, Schoenoplectus, Carex, and Juncus genera, which can also be found in natural wetlands. However, over the last 20 years, ornamental plants have started to make their appearance in constructed wetlands, as they can contribute to the performance of constructed wetlands in the same way as the previously mentioned species. Moreover, their flowers can increase the aesthetic value of these systems, thus simultaneously enhancing their public acceptance. The main goals of the PhD thesis were: a) to examine the performance of vertical flow constructed wetlands planted with ornamental and climbing plants for greywater treatment, focusing on the role of substrate and vegetation , b) to assess the performance of floating treatment wetlands planted with ornamental plants for greywater treatment, with a specific emphasis on the role of buoyant material and vegetation, and c) to assess the level of pollutant, emerging organic contaminants and microfibers removal in VFCW systems for real laundry wastewater treatment. In the first part of the current study, the use of climbing ornamentals and ornamental plants for greywater treatment in vertical flow constructed wetlands, was investigated. Different design parameters, such as substrate (sand or vermiculite), the use of saturation zone, and plant species (Trachelospermum jasminoides, Lonicera japonica, Callistemon laevis) were evaluated for optimal removal of studied pollutants. Results revealed that, regarding the tested substrates, sand with or without saturation zone presented significantly higher removal rates for turbidity (94 ± 5 %) and Chemical Oxygen Demand: (96 ± 7 %) than vermiculite (Turbidity: 54 ± 23 %; Chemical Oxygen Demand: 73 ± 29 %). Moreover, slightly higher removal rates were recorded in vegetated systems compared to unvegetated systems. According to the findings, all examined plants survived and grew in vertical flow constructed wetlands receiving up to 204 mm of greywater per day. However, L. japonica and C. laevis are more well-adapted to such constructed wetland systems compared to T. jasminoides. Overall, the application of climbing and ornamental plants in vertical flow constructed wetlands for greywater treatment in buildings seems like a very promising option to improve the aesthetic appearance of the systems and consequently increase public acceptance. In the second part of the study, the performance and clogging of the vertical flow constructed wetlands (VFCWs) previously mentioned, after two years of operation at mesocosm level, was investigated. The presence of different substrate (sand, vermiculite) and vegetation (Trachelospermum jasminoides, Lonicera japonica, Callistemon laevis) types were evaluated to determine the optimal removal of pollutants. Results revealed that, during the second year of operation, removal efficiencies of turbidity and COD were significantly higher (1st year: 54–94 %; 71–89 %, 2nd year: 82–98 %; 86–95 %, respectively) for both studied planted substrates, compared to the first year. Moreover, it was found that sand systems from each studied plant as well as from the unplanted systems, were more effective compared to vermiculite for most of the studied parameters (turbidity, TSS, COD, anionic surfactants, pathogens). Sand systems were also quite effective in removing total coliforms (5 log reduction) and Escherichia coli (4 log reduction). At the end of the two-year experiment, all planted systems with sand had significantly higher hydraulic conductivity than the unplanted ones. With reference to evapotranspiration, even though planted systems had significantly higher losses, C. laevis systems demonstrated less water losses than the other vegetated systems. According to the findings, the studied plants managed to continue growing without facing added stress. Therefore, the application of climbing and ornamental plants in VFCWs for greywater treatment in buildings seems a promising option for developing green infrastructures in urban areas and enhancing the removal efficiency of such systems. In the third part of the study, several ornamental plant species (monocultures: Cannasp., Iris sp., polyculture: Iris orientalis, Cyperus sp., Acorus gramineus) were tested in two different types of floating mats, including a media supported floating mat (MSFM) or a simple plastic grid, and evaluated for optimal removal of the studied pollutants. The results regarding pollutant removal revealed that planted systems grown in MSFM achieved significantly higher removal rates (up to 90%) compared to the plastic grid (up to 80%). Statistically significant higher removal rates were obtained for the planted systems compared to the unplanted systems either grown in MSFM (for turbidity (planted: 82 – 90 %; unplanted: 44%), COD (planted: 74 – 84 %; unplanted: 32 %) and BOD5 (planted: 76 – 85 %; unplanted: 51 %), respectively) or grown in the plastic grid (for turbidity (planted: 64 – 78 %; unplanted: 44 %) and COD (planted: 43 – 75 %; unplanted: 32 %), respectively). During the experimental period (7 months), all plants managed to survive and withstand the weather variations. The plants in polyculture followed by Iris sp. plants in plastic grid floating mats were better adapted, as indicated by maximum quantum efficiency of PSII values and chlorophyll content index, while all the plants were considered well adapted in the MSFM. Overall, the implementation of floating treatment wetlands with ornamental vegetation for greywater treatment in urban areas seems to bea sustainable and efficient approach. In the fourth part of the study, the level of the optimal removal of conventional pollutants (turbidity, TSS, COD, TP) and micropollutants (Benzotriazoles: CBTR (5-chlorobenzotriazole), XTR (xylytriazole)) in VFCW systems for real laundry wastewater treatment, as a function of the presence or absence of an ornamental plant(Trachelospermum jasminoides), was evaluated. Results revealed that high removal efficiencies were presented in both studied systems regarding turbidity (planted: 97 ± 2%, unplanted: 98 ± 4%), TSS (planted: 92 ± 9%,unplanted: 97 ± 2%) and COD (planted: 98 ± 2%, unplanted: 98 ± 1%) parameters, indicating that plants’ presence was not the main removal pathway for the studied pollutants. Moreover, it was also demonstrated that no TP removal was noted in the studied systems, which could be deduced to the fact that sand substrate reached its maximum capacity of P sorption. High were also the removal rates of CBTR and XTR, which were the only compounds monitored with high similarity rate (95%), in both VFCW systems (planted: 99.7%; 94%; unplanted: 87%; 92%, respectively). However no statistically significant difference (p > 0.05) was noted between them, indicating that mainly sand substrate contributed to their removal. According to the findings, the application of VFCWs for on-site laundry wastewater treatment in buildings seems to be a highly promising solution, not only for primarily removing conventional pollutants but also for addressing emerging contaminants, specifically BTRs. Additionally, T. jasminoides demonstrated the ability to survive and grow without any visible symptoms under the harsh conditions of laundry wastewater, enabling the development of green facade in buildings. In the fifth part of the study, the removal of fiber microplastics from greywater using a vertical flow constructed wetland (VFCW) was investigated. An experimental wetland was constructed, planted with the flowering plant Zantedeschia aethiopica and filled with a substrate made of sand/gravel of several sizes. The system’s performance was monitored for five months during which it received real laundry wastewater. Promising results were obtained showing the significant removal of microfibers from the influent (> 95%). Moreover, the ability of the system to remove microfibers from laundry wastewater was not significantly affected from the hydraulic loading rate (HLR) applied. The average microfibers concentration decreased from 71 ± 25 microparticles/L in the influent to 1 ± 1 microparticles/L in the effluent of VFCW when an HLR of 63.7 mm/d was applied. High removal efficiencies were also observed for COD and turbidity (93% and 94%, respectively). Thus, the results indicate a significant improvement in the overall quality of laundry wastewater due to the use of the VFCW.

Degree

thesis:*
Grantor dc:publisher
University of the Aegean
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Stefanatou, Aimilia
  • Στεφανάτου, Αιμιλία

Subjects

dc:subject × 42

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/55790

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Stefanatou, Aimilia; Στεφανάτου, Αιμιλία. Study on the performance of constructed wetlands planted with ornamental plants for on-site greywater treatment in urban areas. University of the Aegean, 2024. http://hdl.handle.net/10442/hedi/55790