Abstract
dc:descriptionThe present Doctoral Dissertation examines the Indoor Air Quality (IAQ) after a chemical event in two semi-closed environments, in which their occupants are not familiar with the presence of chemical agents, therefore are not properly prepared to apply emergency measures. For this purpose, the dispersion of ammonia, a low toxicity chemical agent lighter than dry air, and the dispersion of phosgene, a highly toxic chemical agent heavier than dry air, were simulated separately in a typical office space and in the venue "Georgios Milonas" of the University of Ioannina. The chemical agents were released from a source located in the center of each room, at 1.00 m AGL (Above Ground Level). The amount used for each agent, was the largest possible that could be carried into the space by a single person, who would attempt to cause a chemical event without being noticed. Α CFD software was used for the simulations. Initially, the three-dimensional geometric model of each flow field was created using an external CAD software, taking under consideration the structure and the constructive components, the layout of objects in each room, the position of doors and windows, the exhaust ventilation, as well as any other object that could act as an obstacle to the chemical agents’ flow. Subsequently, different three-dimensional structured meshes were generated for each flow field, grid independence tests were performed in order to ensure the solution’s independence from the mesh and finally the mesh that required the least computational power while ensuring reliable results was selected for each case. The dispersion of each chemical agent was simulated separately in each space under the influence of ambient air’s circulation and the available HVAC systems were not put into operation. The dispersion of each chemical agent was observed for 30 minutes after its release. The purpose was to evaluate the natural ventilation’s contribution to the decongestion and decontamination of indoor air, as well as the possibility of forming dangerous areas, mainly near the “human breathing zone”, where the occupants could develop serious and possibly irreversible effects to their health. For this, the chemical agents’ concentrations were compared to the IDLH (Immediately Dangerous for Life and Health) index and the AEGLs (Acute Exposure Guideline Levels) for each chemical agent. The simulations’ results showed that in the case of ammonia, the amount released is incapable of creating a serious chemical event in either space. In both spaces are mainly created low-risk areas, where the occupants can feel mild respiratory irritation, mainly 10 minutes after the chemical agent’s release. The case is clearly severest in the office, where for 10 minutes exposure time, these areas occupy a significant part of the breathing levels’ surface. In the venue, low-risk areas are noticed only around the source, while in the largest part of the space the occupants are unlikely to be aware of ammonia’s presence. In neither space are detected areas where emergency conditions exist, therefore the occupants are unlikely to develop serious, irreversible health problems. The furniture and equipment of the two spaces do not seem to affect the dispersion of the chemical agent in either case. Natural ventilation is considered effective for decongesting the ambient air and restoring IAQ, and the contribution of artificial ventilation is not considered necessary. In the case of phosgene, the amount released, although significantly smaller than that of ammonia, is capable of creating a serious chemical event in both examined spaces. In both spaces are formed dangerous areas in which phosgene’s concentrations have disabling or even lethal effect. The case is clearly severest in the office, where for 10 minutes exposure time, these areas occupy the largest part of the breathing levels’ surface and does not significantly improve 30 minutes after the release. In the venue, the case is severest 10 minutes after the release, when are mainly formed areas in which the phosgene cloud has disabling effect, while there are not formed significantly sized areas where the cloud’s concentration is lethal. The furniture and the equipment, which are close to the ground in both spaces, seem to affect the chemical agent’s flow, since they act as obstacles, preventing it from moving downhill, resulting in clouds of dangerous concentrations close to the breathing zone. Natural ventilation is considered inadequate in restoring the IAQ and the contribution of artificial ventilation is necessary.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Ladia, Evangelia
- Λαδιά, Ευαγγελία
Subjects
dc:subject × 19- Υπολογιστική ρευστοδυναμική
- Τυρβώδης ροή
- Χημικός παράγοντας
- Ποιότητα εσωτερικού αέρα
- Computational fluid dynamics
- Turbulent flow
- Chemical agent
- Indoor air quality
- Φυσική
- Φυσικές Επιστήμες
- Φυσική ρευστών και πλάσματος
- Επιστήμη Πολιτικού Μηχανικού
- Επιστήμες Μηχανικού και Τεχνολογία
- Πολιτική μηχανική
- Physical Sciences
- Natural Sciences
- Physics, Fluids and Plasmas
- Civil Engineering
- Engineering and Technology
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/55853