Back to search

Aristotle University Of Thessaloniki (AUTH)

Αποκατάσταση χρόνιων και μεγάλων ρήξεων του στροφικού πετάλου με τενόντιο εξωυμενικό αυτομόσχευμα: πειραματική μελέτη σε κονίκλους

Abstract

dc:description

Purpose: Experimental studies on animal models have shown that an increase in repair tension of rotator cuff tears is related with detrimental changes to the healing insertion site and that the tension required grows with time following detachment. Therefore, in order to optimize healing in chronic and large tears we have to decrease the tension of repair. Our aim was to investigate whether and how extra-synovial autografts can enhance the reconstruction of chronic and large rotator cuff tears in a rabbit subscapularis model. Methods: Power analysis indicated that a sample size of 8 was required for biomechanical studies to detect a significant difference in ultimate load-to-failure. Twenty rabbits were used to create a large subscapularis tear bilaterally. Six weeks later, the right shoulder of each rabbit was operated to repair the tear with an extra-synovial autograft, whereas the left shoulder did not undergo any surgery. At 6 and 12 weeks after the second procedure, the specimens underwent biomechanical and histological evaluation. Six more rabbits were used only as a normal reference. Results: Biomechanical evaluation demonstrated that the ultimate load to failure of the Graft group (184.1 ± 35.7 N) was significantly higher (p = 0.04) than that of the Defect group (144.5 ± 32.2 N) at 12 weeks after repair, rising to 76% of the normal subscapularis tendon tensile strength. Additionally, the modes of failure were consistent with the biomechanical results. Αt 12 weeks after repair only one specimen of the Graft group failed at the footprint, suggesting strong tendon-to-bone healing and fixation. Histological analysis revealed an enhanced healing environment with neoangiogenesis and decreased inflammatory response at the repair site. Moreover, the tendon maturing score of the Graft group increased substantially from 6 (15.8 ± 0.9) to 12 (23.1 ± 0.6) weeks after repair (p = 0.01). Conclusion: Ex vivo data support the efficacy of extra-synovial autograft interposition in repairing chronic and large rotator cuff tears in a rabbit subscapularis model. The autografts were capable of enhancing the biomechanical properties of the repaired tendons, as evidenced by increased tensile strength, and forming new connective tissue simulating a fibrocartilage zone, as revealed by histological evaluation. Clinical relevance: This study suggests that the extra-synovial autograft is a safe and effective autologous tissue that, in combination with future investigations, can be utilized in rotator cuff reconstruction in humans. Taking into consideration the high number of animal models and different types of grafts utilized in rotator cuff research, this approach also represents a new strategy to study the healing environment after rotator cuff repair.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Pinto, Iosafat
  • Πίντο, Ιωσαφάτ

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/56276

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Pinto, Iosafat; Πίντο, Ιωσαφάτ. Αποκατάσταση χρόνιων και μεγάλων ρήξεων του στροφικού πετάλου με τενόντιο εξωυμενικό αυτομόσχευμα: πειραματική μελέτη σε κονίκλους. Aristotle University Of Thessaloniki (AUTH), 2024. http://hdl.handle.net/10442/hedi/56276