Back to search

University of West Attica

Συστήματα μέτρησης και παρακολούθησης περιβαλλοντικών ρύπων με τη χρήση τεχνολογίας διαδικτύου των πραγμάτων

Abstract

dc:description

The objective of this thesis is to evaluate low-cost air quality sensors and the feasibility of their application and utilization in IoT metering systems for the development of a large spatial coverage air quality monitoring network. Air quality, particularly in large cities, has a direct impact on both the health and lifestyle of citizens. Government agencies and research centers study and monitor air quality, using very expensive equipment, which results in a small number of installed air quality monitoring systems, highlighting the problem of spatial coverage in large areas. In recent years, advances in technology have resulted in the development of low-cost air quality sensors. According to the results of this thesis, these sensors can extract reliable data after applying specific methods of correction and optimization of measurements. By extension, low-cost air quality sensors can be used in IoT devices to deploy dense network. For this purpose, low-cost air quality monitoring stations were constructed, which include a microprocessor unit, gas pollutant, nitrogen dioxide and ozone sensors, a microparticle sensor and a barometric sensor, while the interface with the Internet is provided via a wireless or mobile network. The measurement data are sent from each station and stored in a database, and a data visualization application server has been developed for the visualization of the measurements. The calibration of the low-cost air quality monitoring stations was performed by the method of short-circuiting them next to official measurement instruments, which were used as reference, at the facilities of the National Observatory of Athens. First, the behavior of low-cost sensors was studied, by sensor category, which showed homogeneity in terms of measurements with a very high correlation coefficient. Then in the process of calibrating the measurements against the reference measurements, it was deemed necessary to create a calibration function using two correction factors. The calibration function was confirmed as its application to all the gas pollutant, nitrogen dioxide and ozone sensors showed excellent measurement improvement results, up to 25%. A calibration function was also applied to the microparticle sensors, to which both temperature and ambient humidity contribute as correction factors. During the calibration process it was revealed that the barometric pressure of the environment as a correction factor also contributes to the correction of the measurements. As the pollutant gas sensors have a lifetime of up to two years, the investigation of their behavior during the operating time was also the subject of the study. This research has shown that the measurements are affected during the ageing of the sensors, and their correction is curable by varying the coefficients through an equation that modifies the calibration coefficients during the sensor's operating time. To optimize the measurements, simple linear regression and multiple linear regression models were applied to both the gaseous pollutant sensor measurements and the low-cost microparticle sensor measurements, with coefficients depending on the barometric conditions (temperature, humidity, and barometric pressure). The results showed the importance of the barometric conditions in correcting the measurements. Finite impulse response (F.I.R.) and Kalman filter models were applied as estimators, to the measurements. The results were excellent as they showed an improvement of up to 25% for the F.I.R filter and up to 40% for the Kalman filter. In addition, the determination of safe variation limits for optimizing measurements on low-cost electrochemical air quality sensors was investigated by applying both the mean and median of the variance between measurements from low-cost sensors and reference measurements. The results of this method showed an improvement of the measurements to a satisfactory degree. Finally, the non-linear regression method was applied to the data from low-cost and reference sensors. This method revealed a polynomial function which can be used to optimize the measurements from low cost sensors.

Degree

thesis:*
Grantor dc:publisher
University of West Attica
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Christakis, Ioannis
  • Χρηστάκης, Ιωάννης

Subjects

dc:subject × 38

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/56380

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Christakis, Ioannis; Χρηστάκης, Ιωάννης. Συστήματα μέτρησης και παρακολούθησης περιβαλλοντικών ρύπων με τη χρήση τεχνολογίας διαδικτύου των πραγμάτων. University of West Attica, 2024. http://hdl.handle.net/10442/hedi/56380