Back to search

Aristotle University Of Thessaloniki (AUTH)

Ανάπτυξη στοχαστικού μοντέλου σύλληψης κεραυνού και εφαρμογές του σε συστήματα αντικεραυνικής προστασίας

Abstract

dc:description

The scope of the Ph.D. thesis is the development of a stochastic lightning attachment model in MATLAB software, which is based on the concept of fractal structures, and its application on lightning incidence estimation and shielding design of power systems. Model parameters are selected on a physical basis considering lightning discharge physics as well as field measurements and observations. The model considers the combined effects of: (i) the actual 3D geometry of power systems and the effect of neighboring objects, (ii) the stochastic progression of lightning discharges in a 3D domain, (iii) the inception and propagation of multiple competing upward leaders and the interaction with the downward leader, (iv) the lightning discharge polarity, and (v) the physical processes involved in lightning attachment. The aforementioned parameters are neglected by the conventional deterministic electrogeometric models and leader propagation models, suggested until nowadays by international standards on lightning protection of power systems. Stochastic model’s validity is demonstrated against recent and reliable field observations on lightning discharge propagation, lightning attachment, and induced electric fields, which are available nowadays due to the rapid development of high-speed video recording systems; a satisfactory agreement is found with field data. Generalized methodologies are developed and formulated to quantify lightning incidence results and assess the lightning performance of power systems and are applied in typical substation configurations as well as HVDC and HVAC overhead lines. These methodologies take into account the lightning activity at the location under examination and are combined with electromagnetic transient simulations in ATP-EMTP software to compute the critical currents causing flashover of line insulation. Thus, based on stochastic model results, shielding failure cases can be predicted where the conventional electrogeometric models have reportedly failed in the field. Indicative examples are the recorded shielding failure cases in 500 kV overhead lines of negative shielding angle in Japan, that comprise a topic of continuous research and analysis in the last decade from the scientific community.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Ioannidis, Alexios
  • Ιωαννίδης, Αλέξιος

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/56385

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Ioannidis, Alexios; Ιωαννίδης, Αλέξιος. Ανάπτυξη στοχαστικού μοντέλου σύλληψης κεραυνού και εφαρμογές του σε συστήματα αντικεραυνικής προστασίας. Aristotle University Of Thessaloniki (AUTH), 2023. http://hdl.handle.net/10442/hedi/56385