Back to search

University of Crete (UOC)

Virtual image -based FFR technologies

Abstract

dc:description

Part One. Introduction: Non-invasive methods for assessing fractional flow reserve (FFR) are being actively studied to overcome the limitations of conventional invasive assessment, which requires the use of an intra-arterial pressure wire and administration of hyperemic agents such as adenosine. Angiography-derived FFR (FFRangio) has already demonstrated its diagnostic performance in the context of stable coronary artery disease. However, its application in the setting of non-ST-elevation myocardial infarction (NSTEMI) has not been investigated. Methods: We conducted a prospective, single-center, double-blind study comparing FFR calculated from FFRangio with invasively measured FFR in patients with NSTEMI. FFR was measured in all angiographically intermediate lesions (30%-70% stenosis) and then compared to FFRangio calculated at the same sites. The primary endpoints were the sensitivity and specificity of FFRangio for measuring FFR using a threshold value of ≤0.80. Results: Among 100 NSTEMI patients, 46 patients with 60 vessels were included in the study. The mean FFR was 0.83±0.3 with 22 (36%) being ≤0.80, while the mean FFRangio was 0.82±0.1 with 22 (36%) being ≤0.80. FFRangio demonstrated a sensitivity of 95.5%, specificity of 97.4%, and diagnostic accuracy of 96.7%. Conclusion: FFRangio can accurately and non-invasively assess FFR in NSTEMI and may play a role in guiding treatment decisions related to intermediate coronary lesions in this patient population .Part Two. Introduction: FFRangio and quantitative flow ratio (QFR) are non-invasive methods for assessing FFR, and to date, no comparative study between them in the same patient population has been reported in the literature. Methods: This study is a subset of a larger prospective multicenter single-arm study that included patients diagnosed with NSTEMI, in whom coronary stenosis of 30-70% was evaluated with FFR. FFRangio and QFR were calculated by two different operators and compared with FFR. The two primary endpoints were the comparison of Pearson correlation coefficients between FFRangio and QFR with FFR and the comparison of inter-observer variability. Results: Among the 134 NSTEMI patients screened, 59 patients with 84 vessels underwent FFR measurements and were included in this study. The mean FFR was 0.82±0.40 with 32 (38%) being ≤0.80. The mean FFRangio was 0.82±0.20, and the mean QFR was 0.82±0.30, with 27 (32%) and 25 (29%) being ≤0.80, respectively. The Pearson correlation coefficient was significantly better for FFRangio compared to QFR, with R values of 0.76 and 0.61, respectively (p=0.01). Inter-observer agreement was also significantly better for FFRangio compared to QFR (0.86 vs. 0.79, p < 0.05). FFRangio had a sensitivity of 91%, specificity of 100%, and accuracy of 96.8%, whereas QFR showed a sensitivity of 86.4%, specificity of 98.4%, and accuracy of 93.7%.Conclusion: In NSTEMI patients, both FFRangio and QFR demonstrated excellent diagnostic performance. FFRangio appears to have a better correlation with invasive FFR compared to QFR.

Degree

thesis:*
Grantor dc:publisher
University of Crete (UOC)
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Skalidis, Ioannis
  • Σκαλίδης, Ιωάννης

Subjects

dc:subject × 8

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/56580

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Skalidis, Ioannis; Σκαλίδης, Ιωάννης. Virtual image -based FFR technologies. University of Crete (UOC), 2024. http://hdl.handle.net/10442/hedi/56580