Back to search

National and Kapodistrian University of Athens

Προσαρμοζόμενη ακτινοθεραπεία: φυσικοτεχνικά κριτήρια εφαρμογής στην κλινική πράξη

Abstract

dc:description

Introduction: Advanced techniques in the field of Radiation Therapy, such as Intensity Modulated Radiation Therapy (IMRT), have shown potential for improving tumor control and minimizing damage to critical organs, making them an area of high importance and active research. In comparison to techniques utilized in previous decades, it is possible to monitor changes that occur during treatment to prevent toxicity in patients. In particular, the head and neck region is prone to changes induced by radiation therapy, and these changes can be evaluated over time. Consequently, it is now a common practice to perform replanning when anatomic changes occur during treatment. The primary objective of this study is to quantify dosimetric and anatomic changes that arise in head and neck cancer patients who have undergone IMRT therapy and to determine whether replanning is necessary during treatment. Additionally, the study aims to propose anatomic and dosimetric thresholds that can be used as indicators to determine when Adaptive Radiotherapy should be implemented. Methods and Materials: A total of 31 consecutive patients with various types of head and neck malignancies underwent Intensity Modulated Radiation Therapy (IMRT) treatment. A planning Computed Tomography (CT) scan was performed for each patient, with the respective contours. A primary treatment plan was calculated based on the therapeutic scheme and evaluated using dose volume histogram (DVH). To validate the need for replanning, a repeat CT scan was conducted during the intermediate fraction. For each patient, a hybrid plan was created using the same configuration on the repeat CT, while simultaneously an adaptive plan was created with a new dosimetric plan based on the repeat CT. Both plans were then compared. The patient's position during the treatment course was maintained, both in the primary planning and repeat CT scans, using the same immobilization methods, immobilization devices, and patient position. However, in cases where evident anatomic changes in the external contour occurred, a new immobilization mask was created to properly adjust to the patient's contour due to shrinkage or swelling of the area of interest. Statistical analysis was conducted to evaluate both dosimetric and anatomic deviations of each plan. Results: A statistically significant volume regression of Organs At Risk (OARs) and tumor volume was observed between the primary and repeat CT scans (p<0.05). The Planning Target Volume (PTV) including nodal tissue, responded more to radiation. Substantial reductions were noted in the lateral height at the C2 and T1 vertebral levels in all patients (p<0.001), exhibiting an average decrease of 1.1 cm at C2 and 2.6 cm at T1, respectively. In most of the hybrid plans, the dose coverage of 95% of the tumor volume was lower than the suggested dose levels, violating the required coverage. However, the dose coverage of 50% of the tumor volume, which is a representative absorbed-dose value for the Planning Target Volume (PTV), was comparable in all the plans. The maximum doses observed in the hybrid plans were higher, but the differences were not statistically significant. The dose variations in the critical organs revealed an increase in the mean dose of parotid glands in the hybrid plans compared to the primary and adaptive plans. Similarly, higher maximum doses in the spinal cord and brainstem were reported in the hybrid plans. In some patients, the maximum doses in the spinal cord and brainstem surpassed the dose constraint levels in the hybrid plans.Conclusions: The current study collected and analyzed deviations that occurred during the therapy course to establish thresholds before implementing adaptive radiotherapy. Anatomic changes that lead to deviations in dose coverage could result in overdosage of organs at risk and insufficient dose coverage of the tumor volume. Treatment plans that were created and optimized based on patient anatomy yielded acceptable results for coverage and critical organ sparing. Deviations in patient anatomy that required a repeat CT scan with a new immobilization mask triggered replanning. Based on the findings, the following thresholds may be suggested before implementing Adaptive Radiotherapy: violation in 95% of the dose coverage of 95% of the tumor volume at different tumor volume regions, maximum doses exceeding 50Gy in the spinal cord and 59Gy in the brainstem, neck separation greater than 1cm, and average weight loss exceeding 10% of the initial weight.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Avgousti, Rafaela-Myrsini
  • Αυγουστή, Ραφαέλα-Μυρσίνη

Subjects

dc:subject × 22

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/57027

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Avgousti, Rafaela-Myrsini; Αυγουστή, Ραφαέλα-Μυρσίνη. Προσαρμοζόμενη ακτινοθεραπεία: φυσικοτεχνικά κριτήρια εφαρμογής στην κλινική πράξη. National and Kapodistrian University of Athens, 2024. http://hdl.handle.net/10442/hedi/57027