Μελέτη των παραμέτρων που επηρεάζουν την τελική θέση της αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας σε σχέση με την υπάρχουσα ανατομία - μορφολογία: επίπτωση στη λειτουργικότητα
Abstract
dc:descriptionThe displacement (jump) of the bioprosthetic valve (random displacement) during the final stage of its release from the delivery system, following pigtail removal and bioprosthesis’ contact with the left coronary cusp (which is not under operator’s control), seems to be affected by the anatomical and morphological characteristics of the adjacent structures, such as left ventricle, interventricular septal thickness, aortic annulus and ascending aorta. The aim of this study was to detect the anatomical and morphological differences between patients in whom the implantation depth of the bioprosthetic aortic valve during the final stage was not followed by displacement (Group 1: implantation was not followed by displacement and implantation depth was measured at 4-8mm from the level of the aortic annulus in all coronary cusps) and those whose high displacement was observed during the final phase of bioprosthesis expansion (Group 2: implantation was followed by displacement and implantation depth was <4mm, from the level of the aortic annulus, at least in one coronary cusp).A total of 120 patients, aged 80.49±7.22 years old, 57 men (47.5%) with symptomatic severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) with Medtronic CoreValveTM system were analyzed (Group 1: 65 patients and Group 2: 55, respectively). Patients’ demographic, anatomical and morphological characteristics did not differ significantly between the 2 groups, apart from the past medical history of arterial hypertension (Group 1: 87.7% vs Group 2: 72.7%, p= 0.038) and chronic obstructive pulmonary disease (Group 1: 43.1% vs Group 2: 16.4%, p= 0.002). Balloon predilatation was performed in 45% of the patients (Group 1: 47.7% vs Group 2: 43.6%, p= 0.657). Device success was 95% (Group 1: 92.3% vs Group 2: 98.2%, p= 0.141). The displacement of bioprosthesis towards the non-coronary cusp was greater in Group 2 (A: 1.28±0.93mm vs B: 3.12±1.94mm, p <0.001). Myocardial injury was significantly lower in Group 2, in all measurements. Moreover, conduction disturbances rates, as well as need for permanent pacemaker implantation after TAVI were lower in Group 2, however without statistically significant difference. No significant differences were observed between the 2 groups regarding bioprosthesis functionality immediately after TAVI and during follow-up at 1 and 6 months. After further analysis of the possible parameters that may affect the final implantation depth, we found that medical history of arterial hypertension and chronic obstructive pulmonary disease play an important role, as well as the evolution of bioprosthesis’ design, which significantly affected also the occurrence of conduction disturbances.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Bei, Evangelia
- Μπέη, Ευαγγελία
Subjects
dc:subject × 14- Στένωση αορτικής βαλβίδας
- Διακαθετηριακή εμφύτευση αορτικής βαλβίδας
- Αυτοεκπτυσσόμενη βιοπροσθετική αορτική βαλβίδα
- Βάθος εμφύτευσης
- Aortic valve stenosis
- Transcatheter aortic valve implantation
- Self-expandable bioprosthetic aortic valve
- Implantation depth
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Καρδιολογία και Καρδιοαγγειακά νοσήματα
- Clinical Medicine
- Medical and Health Sciences
- Cardiology and Cardiovascular Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/57340