Back to search

National and Kapodistrian University of Athens

Επίδραση της απολύμανσης της επιφάνειας εμφυτευμάτων στη διάλυση του τιτανίου

Abstract

dc:description

Introduction: Dental biomedical implants have a long history of successful human application and have been established as an evidence based preferred treatment modality for the rehabilitation of tooth loss. Their high osseointegration and functional loading success rates are well documented. However, concerns have been raised in the literature regarding the increasing prevalence of peri-implantitis, which exceeds 10% of implant patients across epidemiological studies. Peri-implantitis is a local infection in the tissues surrounding dental implants and is associated with inflammatory symptoms, bone loss, and discomfort. Despite numerous treatment efforts for peri-implantitis, current therapeutic approaches usually yield only short-term therapeutic benefits, with some interventions showing up to 100% disease recurrence after 12 months. Due to the similarities in location (i.e., oral biofilms) and clinical signs (e.g., peri-implant swelling and bleeding on probing) between periodontitis and peri-implantitis, research has suggested that bacterial biofilms, which are the etiological factors triggering immune responses and causing periodontal inflammation around teeth, are also responsible for inflammation around implants. Interestingly, the results of antimicrobial therapies against peri-implantitis are not favorable and only provide short-term benefits with disease relapse. New research data demonstrate that the pathogenic mechanism of peri-implantitis is highly complex, and besides the microbial factor, titanium surface corrosion of the implants contributes significantly to inflammation, similarly to the causative role of microbial biofilms in the pathogenesis of peri-implant inflammation. Even though previous studies have contributed to understanding the fact that the etiology of peri-implantitis is multifactorial, involving both microbial factors and titanium corrosion, there is a critical gap in the literature regarding the etiology of titanium corrosion and, consequently, its prevention. Given that thousands of dental implants are placed daily on a global scale, it becomes increasingly important to investigate the sources of titanium corrosion in peri-implantitis, both for primary prevention and treatment. Aim and Scope: The aim of this laboratory study is to extensively investigate the effect of mechanical and chemical disinfection methods used in clinical practice, which could potentially contribute to implant corrosion, titanium dissolution, and loss of cellular compatibility. To achieve this objective, we will evaluate the following specific aims:1)The dissolution of titanium from the implant surface depends on the applied mechanical or chemical cleaning process.2)The iatrogenic "damage" to the titanium dioxide passivation layer hinders its cell compatibility with osteoblastic cells. The findings from the proposed study will provide better insight for clinical decision-making regarding peri-implantitis treatment strategies. Materials and Methods: This laboratory study was conducted from August 15, 2017, to September 14, 2023, at the Department of Physiology, Medical School of the National and Kapodistrian University of Athens, in collaboration with the Periodontology Research Laboratory of the Dental School of the National and Kapodistrian University of Athens and the Translational Periodontal Research Lab of the University of Texas Health Science Center at San Antonio, USA. An in vitro "ecological" experimental model was used in the study, which was based on titanium discs (10 mm in diameter) covered with microbial plaque to simulate the laboratory conditions of dental implants under the influence of microbial plaque as encountered clinically during peri-implantitis. A total of 240 titanium discs were used, which were subjected to inoculation with a clinical sample of peri-implant plaque in the form of microcosm biofilms. The experimental groups included clinically applied mechanical and chemical cleaning interventions because the dissolution of titanium from the implant surface depends on the applied surface treatment. The chemical cleaning groups included 1.5% sodium hypochlorite (NaOCl), and 0.12% chlorhexidine (CLX). The mechanical cleaning groups included a nylon brush (Nylon), a titanium brush (Titanium), and pressurized sterile water (WaterJet - WJ). In all groups, the antimicrobial effectiveness was analyzed and the efficacy of microbial biofilm removal was assessed with immunofluorescent staining. Additionally, the effect of each surface cleaning intervention on surface alterations leading to increased titanium particle release from the implant was assessed through artificial aging of the titanium by immersing it in a corrosion-mimicking medium (MEM + 10% FBS) under anaerobic conditions for 4 weeks. The determination of titanium concentration in the media was performed via inductively coupled plasma mass spectrometry, ICP-MS. In the second phase of the research, the effect of the changes on the cytocompatibility of titanium surfaces was evaluated through chemotaxis experiments and osteoblastic cellular attachment. In the third and final phase, the cytotoxicity of the released titanium particles from the surface due to the alterations caused by the cleaning procedures was assessed by measuring lactate dehydrogenase activity after phagocytosis of the particles. Statistical analysis was performed using ANOVA, and post-hoc tests adjusted for multiple testing were used for pairwise comparisons between study groups. Results: The results showed that the examined microbial removal techniques were always associated with reduced cell compatibility compared to control surfaces. Pressure water spraying demonstrated statistically significant higher biofilm removal compared to all other groups (p < 0.05) and demonstrated the highest measurements of viable cells among the other surfaces. Application of chlorhexidine exhibited the lowest number of viable cells and significantly more dead cells compared to controls (p < 0.05), indicating its documented cytotoxicity. Discussion: This research study investigated whether the disinfection of implant surfaces affects titanium dissolution. For the first time, it was shown that the mechanical cleaning of the titanium surface affects its atomic composition. Furthermore, we demonstrated that surface alterations of titanium are associated with a decrease in its cell compatibility. In the second part, we addressed the question of whether surface alterations lead to increased release of titanium particles from the implant. This question is purely clinical since free titanium particles have been associated with recognition by phagocytes and the release of pro-inflammatory cytokines. Results showed that all surface disinfection interventions led to at least a five-fold increase in the amount of released titanium following the interventions. Specifically, the use of a titanium brush, which was also the most aggressive intervention, was associated with the highest release of titanium particles. This result is consistent with possible adverse biological effects and indeed demonstrated increased cytotoxicity of fibroblasts after 24 hours of titanium stimulation. Overall, the importance of the present findings lies in the cytotoxicity of released titanium particles that arise from implant cleaning interventions. The significance of these findings is high considering regarding that peri-implantitits affects a high proportion of patients with dental implants, while lacking a reliable treatment. Our results suggest that future research should be focused on innovative treatments to remove peri-implant bioflims while limiting the degradation of the biomaterial and the resulting release of particles, which contribute to cytotoxicity in peri-implant tissues

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kotsakis, Georgios
  • Κωτσάκης, Γεώργιος

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/57479

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kotsakis, Georgios; Κωτσάκης, Γεώργιος. Επίδραση της απολύμανσης της επιφάνειας εμφυτευμάτων στη διάλυση του τιτανίου. National and Kapodistrian University of Athens, 2024. http://hdl.handle.net/10442/hedi/57479