Technical University of Crete (TUC)
Ανάπτυξη / βελτίωση μεθοδολογίας για την ανίχνευση στοιχείων της ομάδας του λευκόχρυσου (platinum group metals, PGM) σε υδατικά δείγματα
Abstract
dc:descriptionPlatinum group metals (PGM) are platinum (Pt), ruthenium (Ru), rhodium (Rh), palladium (Pd), osmium (Os), and iridium (Ir). They are metals that are found in the Earth’s crust in very small concentrations yet have unique applications and can be irreplaceable in many of them, such as in catalysis, in the chemical industry, medical applications and electronic applications, in alloys that significantly improve resistance to corrosion and high temperatures. They have been included in the lists of critical metals of the United States of America and the European Union. Due to their unique applications, their price is traded on the metal exchange and, for some of them, is a lot higher than the price of gold. Their distribution in the environment and their bioaccumulation have not yet been systematically investigated, and the existing data on the possible toxicity of their residues, both in organisms and in the environment, are limited. This means that there is a need for alternative methods for their chemical analysis in the different parts of the environment. Increasing interest has been observed in recent years for environmental studies based on X-ray Fluorescence, due to the requirements of green Analytical Chemistry. Complexing membranes have been used in the past by the Analytical and Environmental Chemistry Laboratory of the Technical University of Crete to selectively preconcentrate various metals and ions from aqueous samples. This work, attempted for the first time to prepare complex membranes for the preconcentration and determination of platinum group elements in aqueous samples in combination with energy-dispersive X-ray Fluorescence (EDXRF). Platinum was thoroughly studied and the procedures, that gave especially satisfactory results, were tested on the other elements of the PGM group. For the experimental studies of this thesis, selective complexing membranes were prepared. An adequate number of different complexing agents were tested, and the composition of the membranes was investigated. Anionic and cationic membranes, as well as membrane aging, were tested. The distribution of platinum ions on the membrane surface and the effect of the addition of various salts to the aqueous solution on the X-ray performance of the metals was examined. The effect of pH, the optimal solution volume, as well as the necessary equilibration time, were investigated. The most efficient irradiation conditions were tested and the effect of various interfering elements, commonly present in natural waters, was examined. The effect of water hardness was studied, both on the minimum detection limits and on the recovery, while the appropriate research and selection of an internal standard was made to improve the repeatability of the method, which is a critical parameter. Different contacting ways between the membrane and the metal ions in the aqueous solution were investigated, to increase the complexing result. Thus, the liquid membrane solution was prepared and allowed to dry in various ways. The solidified membrane was introduced into the aqueous solution and, after a certain time, collected and analyzed by EDXRF. The membrane was placed on the surface of a thin film in different ways; drops of the liquid membrane were placed on the surface of a big magnet that was immersed and rotated in the solution. Free self-supporting membranes were also investigated. A self-supporting membrane is a very thin layer of free membrane that was immersed and swirled throughout the aquatic solution, which was continuously stirred with a magnetic stirrer. After removing the membrane from the aqueous solution, it was redissolved in tetrahydrofuran (THF) solvent and allowed to solidify as a small spot on a thin film surface. The detection was carried out by Energy Dispersive X-ray Fluorescence (EDXRF), while two different systems were compared, one with a Si-Pin detector and a silver mini-X-ray tube and another with a silicon drift detector (SDD) and a palladium X-ray tube. After the above experimental processes, significant improvements were made in the methodology for detecting platinum from aqueous samples. Self-supporting free membranes were used for the first time and proved to be very effective in capturing platinum with very high recovery rates of 90% or greater. A minimum detection limit for platinum, less than 100 ng/L (parts per trillion), was achieved from the aqueous samples in deionized and seawater samples. Increasing the volume of the aqueous sample can improve (lower) the minimum detection limit of the method, but the recovery is reduced. Detection limits of 180 ng/L and 100 ng/L were achieved for the iridium and osmium, respectively. For palladium and rhodium, the detection limits were 20-40 µg/L, while for ruthenium the detection limit was 380 µg/L. The method gave equally good results in all types of natural waters such as lake water, river water, bottled water, and seawater which is a difficult matrix for several analytical techniques. The most common elements in different types of aqueous samples were introduced at high concentrations in the aqueous solutions and caused no interference with platinum performance. Good linearity was achieved for platinum and most of the other PGM elements, over a wide range of concentrations.
Degree
thesis:*- Grantor dc:publisher
- Technical University of Crete (TUC)
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Vlamaki, Georgia
- Βλαμάκη, Γεωργία
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/57531