National and Kapodistrian University of Athens
Συσχέτιση και συνεκτίμηση US δεικτών καρδιακής λειτουργίας με MRI μετρήσεις εναπόθεσης σιδήρου στην καρδιά ασθενών με μεσογειακή αναιμία
Abstract
dc:descriptionBackground and objectives: Despite advances in survival in patients with thalassemia major (TM) the most common cause of death is cardiac disease. Regular cardiac follow-up is imperative in order to identify and reverse pathology. Cardiac Magnetic Resonance (CMR) and Echocardiography (US) are applied in parallel to TM patients for cardiac evaluation and ongoing monitoring. Moreover cardiac iron load can be indirectly quantified by CMR’s T2*. However CMR accessibility is limited, whereas US is relatively inexpensive and readily available. The objectives were to find US parameters that may be useful for predicting cardiac iron and to assess the accuracy and reliability of the two methods, with a particular focus on routine US application. Design and methods: We correlated a number of parameters derived from US to CMR’s T2* score in 142 TM patients and compared common volumetric measurements between the two techniques Results: All patients with decreased left ventricular (LV) shortening fraction (LVSF ? 30%) had cardiac iron overload (T2* ? 15 ms). After removing these patients from the analysis, the total diameter index (Tdi) >5.57 cm/m2, left atrial diameter index >2.41 cm/m2, and the diastolic parameter E/A >1.96 were highly specific (91.4%, 97.1% and 96.9% respectively), but had low sensitivity (31.8%, 20.5% and 21.8%), in predicting iron load. A right ventricular index >1.47 cm/m2, LV systolic index >2.26 cm/m2 or Tdi >6.26 cm/m2 discriminated between patients with severe load from those with none to moderate cardiac iron load, with specificity of 91%, 98.5%, and 98.5%, respectively, but again with low sensitivity. In addition while comparing the common volumetric parameters between CMR and US (Teichholz's M-mode formula) we found that the correlation for the ejection fraction (EF) was acceptable (r=0.60) without a statistically significant difference (p=0.37) and the Bland & Altman plot range was narrow (25.8%) Interpretation and conclusions: US parameters for cardiac iron overload prediction have limited value, whereas CMR is essential in assessing cardiac iron. However, patients with decreased LVSF (? 30%) should be considered a priori as having cardiac iron overload (T2* ? 15 ms), and chelation therapy should be intensified. This also applies to patients who meet the above-described US criterion values, whenever CMR is not available. Once a patient is found by CMR to have cardiac iron overload, then the fore-mentioned US criterion values may be useful for ongoing monitoring. US also offers an adequate EF estimation with Teichholz's M-mode formula for routine use, especially when monitoring gross alterations in cardiac function over time, and is easy to perform compared to the high resolution CMR technique.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Γιακουμής, Αναστάσιος
- Giakoumis, Anastasios
Subjects
dc:subject × 20- Εξαρτώμενη από μεταγγίσεις β-μεσογειακή αναιμία ( νόσος του Cooley)
- Σίδηρος, Υπερφόρτωση
- Υπερηχοκαρδιογραφία ( US)
- Καρδιακός μαγνητικός συντονισμός (CMR)
- Αποσιδήρωση, Θεραπεία
- Ογκομέτρηση και κλάσμα εξώθησης (EF)
- Προσδιορισμός καρδιακού φορτίου σιδήρου (Τ2* και R2*)
- Προβλεπτική αξία υπερηχοκαρδιογραφικών (US) παραμέτρων
- Transfusion dependent β-thalassemia ( Cooley’s disease)
- Iron overload
- Echocardiography
- Cardiac Magnetic Resonance (CMR)
- Chelation theraphy
- Volumetry and ejection fraction (EF)
- Quantification of cardiac iron load (T2* and R2*)
- Predictive value of echocardiographic (US) parameters
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/5802