University of Patras
Επίδραση διαφορετικών ρυθμίσεων συχνότητας και έντασης του λιθοτρίπτη laser στην ενδονεφρική θερμοκρασία κατά τη διάρκεια λιθοτριψίας με εύκαμπτο ουρητηροσκόπιο
Abstract
dc:descriptionLithiasis is one of the most frequent pathological entities of the urinary system. Ureteroscopy and laser lithotripsy is one of the basic surgical approaches to treating stones in the armamentarium of urologists. The development of high-power laser devices has been a major factor regarding the advancements of the aforementioned surgical procedure. Increased intrarenal temperature and potential renal damage are associated with multiple factors when high-power laser is used to fragment stones. In the present study we investigated the factors that may affect the intrarenal temperature, with limits of 43°C and 54°C as recommended by the present literature. For the in vitro experimental study we used a 20 ml syringe, a 14/12 ureteral sheath, a dual-lumen catheter and a K-type thermocouple for the recording of the intrarenal temperature. The Quanta Ho 150W was used with settings 10W to 60W. These power settings were tested in different conditions: fibers (200-550μm), volumes (5ml-20ml) and artificial stones (hard, soft). In all tests, 60W resulted in a higher temperature elevation. No difference was observed when different fibers were used. The highest temperatures (up to 80°C) for 60 W were reported with a 5 ml syringe and the lowest (<45 0 C) with 20 ml. The temperature exceeded 43°C when power settings >40W were applied. For the in vivo part of the study we used female pigs. In the first experimental study, percutaneous access was achieved and a 30Fr sheath was placed within the pelvicalyceal system for the insertion of the thermocouple. A Lumenis 120H Ho:YAG laser with settings 20W-60W was used. The laser was activated under gravity and manual pump irrigation conditions using MOSESTM pulse modulation technology and conventional pulse. No difference in temperature elevation pattern was shown between the two approaches. Based on the same experimental set-up, artificial stones were introduced into the pelvicalyceal system. Stone fragmentation was achieved using Quanta Litho Cyber Ho 150WTM without ureteral access sheath, and with gradually increasing sheat up to 14/16 and power settings of 20W-100W both with manual pump as well as gravity irrigation. Temperature elevation above 54°C was recorded above 40W when gravity irrigation was used. The use of a ureteral access sheath prolonged the temperature elevation time, although high power settings increased the temperature within seconds of laser activation. When irrigating with a manual pump, only the laser activation with 100W and without the use of a sheath resulted in the temperature rise outside the safety limits within just 10 seconds. Finally, two pigs were used for the histopathological evaluation of temperature increase. After inserting a ureteral sheath, activation of the TFL laser (Quanta Fiber Dust, Samarate, Italy) was performed to maintain the temperature above 43°C. The first of the pigs was anesthetized 1 week after the procedure. Flexible nephroscopy followed by right nephrectomy was performed. The second pig underwent the same procedure 2 weeks after the initial operation. The histopathological report revealed severe alterations in the kidney of the first pig and milder in the kidney of the second pig. Based on our results, the conditions for safe high-power lithotripsy are the use of a ureteral access sheath, the use of a manual irrigation pump and intermittent laser activation.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Peteinaris, Angelis
- Πετεινάρης, Αγγελής
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/58555