Back to search

Aristotle University Of Thessaloniki (AUTH)

Διερεύνηση της επιρροής των συμβατικών λύσεων ενεργειακής αναβάθμισης στην αντισεισμική συμπεριφορά τοιχοπληρωμένων πλαισίων οπλισμένου σκυροδέματος, με πειραματικές, αριθμητικές και αναλυτικές μεθόδους

Abstract

dc:description

This doctoral dissertation focuses on the experimental, numerical, and analytical investigation of the behavior of infilled frames and the quantification of the influence of thermal insulation systems on their seismic response. The wide context of the research pertains to the integration of common energy upgrade practices into the seismic design of structures. The experimental investigation starts with material testing and extends to full-scale specimens of infilled frames with attached external thermal insulation solutions. In particular, the mechanical response of thermal insulation systems using rock wool, expanded polystyrene, and extruded polystyrene with thickness of either 50mm or 100mm was studied. As part of this dissertation, more than 350 material tests were conducted (on clay bricks, mortars, insulation materials, mesh and anchors). Additionally, 37 triplets were tested under compression, shear or bending to investigate the basic mechanical characteristics of masonry. The interaction between thermal insulation systems and the masonry substrate was quantified through more than 70 tests, assessing the developed stress field both parallelly and perpendicularly to the wall plane. The in-plane behavior of masonry structural elements, with or without attachments, was examined using 22 specimens subjected to diagonal compression tests. The out-of-plane behavior about the horizontal and vertical axes was investigated with 16 and 9 wall specimens, respectively, under cyclic seismic-type loading. Furthermore, a total of 6 large wall specimens were tested under a combination of in-plane and out-of-plane loads. Finally, the study of infilled frames included 6 different specimens. In total, more than 500 laboratory measurements were performed at the Laboratory of Experimental Strength of Materials and Structures. Apart from the bare/virgin and the insulated walls, pre-cracked specimens with interventions, mainly using thermal insulation system materials such as mortar and mesh, were also examined. Simultaneously, and in full correlation with the experimental campaign, numerical simulation methods were developed to replicate the laboratory tests. Various masonry modeling methodologies were evaluated based on their complexity, accuracy, and computational cost. The validated models were used to extend the investigation through additional parametric analyses. Specifically, masonry was modeled as a macro-model (homogenized material), a micro-model (discrete units and interfaces), and a two-material macro-model, where, using cad software, finite elements were differentiated to represent either the masonry units or the mortar. In all cases, the calibration process was performed through the simulation of relatively simple material and triplet tests. Comparing the examined modeling methodologies, macro-models require the least time for development and the lowest computational cost for analysis. However, it cannot simultaneously capture the interaction effects of in-plane and out-of-plane loading. Micro-models and two-material macro-models can predict both in-plane and out-of-plane responses. Between these two approaches, the computational cost of the micro-model is significantly higher, nearly double. In general, all numerical methods can predict masonry behavior and the contribution of attachments with satisfactory convergence in terms of load-bearing capacity, initial stiffness, nonlinear response, and failure modes. The results of the experimental and numerical investigations were assessed to develop analytical prediction formulas for the effect of in-plane loading on the out-of-plane load-bearing capacity. A comparison of the proposed formulas with experimental data from literature displays a satisfactory agreement within specific in-plane drift levels. Additionally, an attempt was made to modify the Eurocode 6 formula in order to calculate the ultimate lateral load capacity of infill walls, which applies to bare/unreinforced walls, to account for the influence of thermal insulation systems on load-bearing capacity. This effort led to a new analytical formula incorporating a modification coefficient, primarily based on the stiffness ratio between the original and "reinforced" walls. The present study highlighted the critical importance of boundary conditions, namely the interface between the infill and the structural frame. Poor confinement conditions significantly increase the vulnerability of infill walls by both reducing their load-bearing capacity and increasing displacement and force demands. The examined infill walls and the thermal insulation systems, applied in the laboratory, demonstrated satisfactory performance in relation to demand levels. However, it should be noted that proper construction practices were followed in the laboratory for building both the masonry and the thermal insulation systems. In all cases, premature failure—detachment of the insulation—before any damage appeared in the masonry substrate was not observed. Therefore, the construction of external thermal insulation systems according to the accompanying ETAG guidelines results in an acceptable performance. In conclusion, it can be argued that energy upgrades involving the addition of thermal insulation should ideally be combined with the retrofitting of the internal face of the infill wall, using appropriate fiber-reinforced coatings, such as those examined in this study. This approach improves both the in-plane and out-of-plane load-bearing capacity, enhances the deformability of unreinforced masonry, and protects both the unreinforced masonry and the insulation from damage, which is difficult to repair when subjected to seismic loading.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Melidis, Lazaros
  • Μελίδης, Λάζαρος

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/58634

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Melidis, Lazaros; Μελίδης, Λάζαρος. Διερεύνηση της επιρροής των συμβατικών λύσεων ενεργειακής αναβάθμισης στην αντισεισμική συμπεριφορά τοιχοπληρωμένων πλαισίων οπλισμένου σκυροδέματος, με πειραματικές, αριθμητικές και αναλυτικές μεθόδους. Aristotle University Of Thessaloniki (AUTH), 2025. http://hdl.handle.net/10442/hedi/58634