Institutes outside Greece
Nonlinear seismic modelling of concrete gravity dam-foundation systems using the Distinct Element Method
Abstract
dc:descriptionVery little is known about the influence of saturated joints in rock and concrete on the seismic performance of concrete gravity dams. The main aims of this study were (i) to evaluate the suitability of the distinct element method (DEM) for the numerical analysis of this problem, and (ii) to extend understanding of this phenomenon by application of the DEM to the analysis of a typical 2-D gravity dam system. The analyses used the UDEC computer program. Numerical modelling of a published wedge splitting test of a concrete specimen with internal pore pressure showed good comparisons with the test data. During concrete cracking, water pressures were rapidly developed. During sudden closure of the concrete crack, water pressures inside the crack were increased up to 3,68 times the origincal static pressures. Fluid flow was not fast enough to dissipate these pressures. As a result, tensile stresses were observed near the crack tip, which is consistent with the idea of the water, being stiffer than concrete, acting as a fulcrum at the crack tip. Numerical analyses of a prototype dam-foundation system wre conducted to study the effect of dynamically induced uplift pressures along the dam-foundation interface. In the case of dynamic uplift pressures, the dam's sliding displacement at the end of the earthquake was considerably influence by the choise of fluid flow model. With a compressible fluid and no flow permitted, unrealistic pore pressure levels built up, reducing the shear strength and inducing severe sliding displacements. When fluid flow was permitted, pore pressure levels were reduced significantly. The sliding displacements accounting dynamic pressures were at least 40% larger, compared to steady pressures. It was concluded that the compressible flow model gives the most realistic results, but the computation times can be an order of magnitude greater than if flow is suppressed. A simplified, faster executing, incompressible model with no flow gave sliding displacements of a similar magnitude to the compressible flow case, suggesting that it might be used at least for preliminary analyses. The influence of the foundations rock mass quality on the nonlinear seismic responce of a dam-foundation system was explored. It was concluded that the system's dynamic response was highly nonlinear and thus susceptible to small parameter changes, which produced significant respose variations indicatind a chaotic-like behaviour. The contral parameter-respose diagrams showed a clear fractal structure, as evidence of the non-linear sensitivities. This implies that broad parametric studies should be conducted when evaluating the nonlinear response of concrete gravity dams, preferably using the full compressible flow model. However, given the computation times involved using current typical office computers, such studies are unlikely to be viable for some years. The UDEC code itself gave plausible results, which should be validated against experimental data.
Degree
thesis:*- Grantor dc:publisher
- Institutes outside Greece
- Year dc:date
- 2006
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Lazaridis, Theologos
- Λαζαρίδης, Θεολόγος
Subjects
dc:subject × 13Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/59207