Μελέτη οπτικού πεδίου με τη χρήση ενός νέου οπτοτύπου TS (Tsiogka/Spaeth) Grid
Abstract
dc:descriptionBackground/Aims: The TsiogkaSpaeth (TS) grid is a low-cost, portable, and easily accessible tool designed for visual field (VF) screening. It could be used in everyday practice by clinicians to assess visual field defects. This study evaluates the accuracy and validity of the TS grid test in identifying VF defects associated with glaucoma and neuroophthalmic diseases. Methods: Two groups of participants were enrolled: patients with glaucoma and patients with neurological diseases that can lead to VF defects versus controls. Eyes of all participants were assessed using the TS grid test and the Humphrey Visual Field Analyzer (HFA) 24-2 as the reference standard. Sensitivity, specificity, positive predictive value, negative predictive value, and the Area Under the Curve (AUC) of the TS grid were calculated based on HFA results. Results: In the glaucoma study, 19 patients had glaucomatous defects in both eyes, 12 had defects in one eye only, and 21 had no defects in either eye. The sensitivity and specificity of the TS grid test for detecting glaucoma-related VF defects were 81.63% (95% CI 68%-91.2%) and 84.91% (95% CI 72.4%-93.3%), respectively. In the neuroophthalmic disease group, 10 patients had visual field defects versus 10 controls. For neurological disease-associated VF defects, the TS grid test achieved a sensitivity of 100% and a specificity of 90.91%. The AUC for the TS grid was 0.83 (95% CI 0.76-0.91) for the glaucoma group and 0.9545 (95% CI 0.87-1.00) for the neurological disease group. There was a significant correlation between the TS grid test scores and the Visual Field Index (r = 0.87, P < 0.0001 for glaucoma, r = 0.9436, P < 0.0001 for neurological diseases). Conclusion: The TS grid test is a reliable, low-cost, and easily accessible method for screening and monitoring visual field defects in both glaucoma and neurological disease patients. It provides high sensitivity and specificity in detecting VF defects, making it an effective alternative to traditional VF testing, especially in settings with limited access to advanced equipment. Despite some limitations, such as challenges with patient fixation and self-administration, the TS grid test could be a valuable tool in clinical practice and in remote or resource-limited areas. Further studies are needed to address these limitations and validate its use for widespread application. Keywords Visual Field, Visual Field Defects, Glaucoma, Neurological Diseases, Humphrey Field Analyzer, The TS Grid
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsiogka, Anastasia
- Τσιώγκα, Αναστασία
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/59262