Back to search

Aristotle University Of Thessaloniki (AUTH)

Καθορισμός των αποκλίσεων τοποθέτησης ασθενών που υποβάλλονται σε καθοδηγούμενη από εικόνα/ανά συνεδρία ακτινοθεραπεία

Abstract

dc:description

This Thesis addresses the comparative assessment of patient setup errors during image-guided radiotherapy (IGRT), through the systematic recording and analysis of data from two imaging modalities: cone-beam computed tomography (CBCT) and planar kV imaging, focusing on four main anatomical sites—prostate, head and neck, lung, and cranial. A total of 178 patients were included in the analysis, each undergoing repeated imaging, with their positioning recorded before every session and corrected based on image guidance. Setup deviations were measured and evaluated along the main spatial axes (X, Y, Z), with analysis also taking into account the treatment day and the time of day (morning or afternoon). All imaging data were subjected to statistical analysis using parametric techniques (t-tests, MANOVA). Initially, the presence of statistically significant differences in mean setup deviations between the two modalities was examined, both per axis and per anatomical area and time of day. Special emphasis was placed on identifying clinically significant deviations, defined as displacements equal to or greater than 1 mm, a threshold considered clinically important according to the capabilities of modern linear accelerators. These cases were investigated comprehensively, per region, axis, imaging method, day, and time, utilizing appropriate indicators and calculating the relative probabilities of occurrence for CBCT versus kV imaging. The results highlighted, for instance, that CBCT is associated with a higher probability of clinically significant displacement for lung (particularly along the Z axis) and cranial (X axis) lesions, thereby underscoring the clinical impact of differences between modalities and anatomical areas. Subsequently, the analysis focused on determining systematic and random errors for each region in order to accurately calculate the planning margins between the Clinical Target Volume (CTV) and Planning Target Volume (PTV) according to the Van Herk formula. The feasibility of asymmetric margin determination was also evaluated: setup deviations were categorized as positive (anterior, right, superior) and negative (posterior, left, inferior), and where statistically significant differences were identified, asymmetric margins were calculated separately. The analysis showed that for some areas, such as lung and cranial, asymmetric margins may more accurately reflect the actual geometric uncertainty, thus optimizing dosimetric safety and accuracy in radiotherapy. Overall, the findings underscore that CBCT tends to yield larger setup deviations in specific directions and anatomical areas, while both the area and the day of treatment significantly affect the measured errors. In contrast, the time of day (morning or afternoon) did not demonstrate a substantial effect. The thorough analysis of clinically significant deviations and the determination of customized planning margins—either symmetric or asymmetric—add practical and innovative value to the dissertation, reinforcing the modern trend toward individualized, evidence-based radiotherapy. The study concludes that optimizing margin design based on both statistical and clinical impacts can enhance therapeutic accuracy and meaningfully contribute to the improvement of clinical IGRT protocols.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Katrakylidou, Eleni - Styliani
  • Κατρακυλίδου, Ελένη-Στυλιανή

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/59808

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Katrakylidou, Eleni - Styliani; Κατρακυλίδου, Ελένη-Στυλιανή. Καθορισμός των αποκλίσεων τοποθέτησης ασθενών που υποβάλλονται σε καθοδηγούμενη από εικόνα/ανά συνεδρία ακτινοθεραπεία. Aristotle University Of Thessaloniki (AUTH), 2025. http://hdl.handle.net/10442/hedi/59808