Back to search

National Technical University of Athens (NTUA)

Συμβολή στη μελέτη γεννητριών ηλεκτροστατικής εκφόρτισης

Abstract

dc:description

This thesis investigates technical challenges associated with immunity testing against electrostatic discharges, within the framework of the IEC 61000-4-2 Standard, with particular emphasis on the implications of its recent (2025) revision and the influence of the human operator. A central focus of the work is the analysis of the newly introduced requirement for monitoring the second portion of the discharge current waveform through the IP2 parameter, as defined in the third edition of the Standard. This change may render many existing generators non-compliant, leading to significant technical and economic implications for accredited laboratories. As a response, a practically feasible and technically substantiated solution is proposed, based on the use of clamp-on ferrites applied to the grounding cable, enabling the reshaping of the waveform without modifications to the internal structure of the electrostatic discharge generator. The thesis provides, for the first time, a comprehensive experimental assessment of the influence of the human operator on the discharge current waveform, analyzing deviations in critical parameters (such as IP2, I30, and I60) and spectral distortions that predominantly occur after the first peak. In parallel, it evaluates the ability to replicate this influence through clamp-on ferrites under various grounding cable arrangements. Variations in ferrite position and type are investigated, along with the robustness of the proposed methodology through a Monte Carlo sensitivity analysis. The next part of the thesis focuses on enhancing the reproducibility between automated and conventional electrostatic discharge testing setups, by evaluating the use of metallic robotic arms. The impact of grounding conditions, contact resistance, and ferrite placement on waveform characteristics is examined, aiming to emulate human presence and achieve measurement consistency. It is demonstrated that, with appropriate parameter tuning, the robotic setup can effectively replicate the operator’s influence. Moreover, the operator’s effect on indirect discharges to the horizontal and vertical coupling planes is studied under realistic test conditions, showing that it not only alters the current waveform but can also affect the immunity performance of the equipment under test. The partial mitigation of these effects is explored through technical countermeasures such as protective gloves and footwear. The overall contribution of the thesis lies in the development of a quantitatively substantiated and practically applicable framework for reliable and fully compliant automated electrostatic discharge immunity testing, aligned with the stringent requirements introduced in the third edition of the IEC 61000-4-2 Standard.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Papastamatis, Panagiotis
  • Παπασταμάτης, Παναγιώτης

Subjects

dc:subject × 26

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/59995

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Papastamatis, Panagiotis; Παπασταμάτης, Παναγιώτης. Συμβολή στη μελέτη γεννητριών ηλεκτροστατικής εκφόρτισης. National Technical University of Athens (NTUA), 2025. http://hdl.handle.net/10442/hedi/59995