National and Kapodistrian University of Athens
Development of aptamer - based biosensors
Abstract
dc:descriptionThis Thesis explores the characterization and the application of aptamers in biosensors. The work is divided into two major parts. The first focuses on the comprehensive selection and evaluation of aptamer candidates for aflatoxin M1 (AFM1) and oxytetracycline (OTC). This process involved an in-depth biophysical characterization employing multiple techniques, including fluorescence polarization, circular dichroism (CD), isothermal titration calorimetry (ITC), induced circular dichroism (ICD), and thermal denaturation studies. These methods were used, not only to confirm binding affinity and specificity, but also to unravel secondary structure dynamics, binding thermodynamics, and conformational changes upon aptamer-target interaction. Importantly, the use of ICD in aptamer studies is introduced here for the first time. The second part of the thesis applies the most promising aptamer sequences in the design and development of fluorescence-based biosensors. These biosensors were implemented both in solution and on plastic surfaces. Among the sensor designs developed, a novel triple-helix-based sensor for AFM1 and aflatoxin B1 (AFB1) detection stands out, contributing an innovative structural approach to the aptasensor repertoire. The thesis underscores that a direct correlation exists between the comprehensive aptamer characterization and the subsequent performance, stability, and reliability of the biosensors constructed. One of the central findings of this research is that not all aptamers perform as reported in the literature. Many existing aptasensor platforms suffer from inconsistent or irreproducible results, a challenge that often stems from the absence of thorough biophysical validation of the aptamer-target interaction. This study reinforces the necessity of adopting robust characterization protocols and highlights that sensor performance cannot be separated from aptamer quality. The broader implication of this work extends beyond the specific analytes addressed here; it serves as a critical paradigm to the aptamer research community to re-evaluate existing practices and to promote more stringent standards in aptamer validation. Ultimately, this Thesis not only delivers novel biosensor platforms but also establishes a methodological framework for aptamer selection and validation that can be applied across diverse analytical contexts, with particular relevance to food safety.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Melios, Nikitas
- Μέλιος, Νικήτας
Subjects
dc:subject × 16Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/60499