National and Kapodistrian University of Athens
Συνεχής επισκληρίδιος έγχυση οπιοειδούς με χρήση αντλίας κατά την επισκληρίδιο αναισθησία σε γυναικολογικές επεμβάσεις
Abstract
dc:descriptionThe aim of the present study was to compare the analgesic effect and the influence on stress response of two intraoperative analgesic techniques applied during epidural anaesthesia for major gynaecological procedures. We studied 40 ASA l-ll patients aged 41-62 years old undergoing total vaginal hysterectomy under epidural anaesthesia. The patients were randomly divided into two groups A and Β depending on the analgesic technique used. The epidural technique was the same for both groups; the appropriate dose of local anaesthetic (bupivacaine 0,5%) was injected in the epidural space so that a T₁₀-S₅ sensory blockade could be achieved. Right after the local anaesthetic infusion an initial dose of 1,5μg/kg fentanyl was injected in the first group (A) while in the second group (B) a continuous epidural infusion of 0,7 μg/kg/h fentanyl (solution of 300 pg fentanyl in 30 ml N/S) started, using a pump, that lasted throughout the procedure. Onset and duration of T₁₀ sensory blockade, visual analogue pain score, pulse rate, blood pressure, respiratory rate, nausea, vomiting and shivering rates were recorded during the surgical procedure in both groups. Arterial blood gas values (PaO₂, PaCO₂) and serum Cortisol and prolactin levels were also measured intraoperatively in both groups. The following results were noted: 1) The onset of anaesthesia was significantly shorter in group A (p<0.05) but the duration of sensory blockade (T₄-I₅) was significantly longer in group B (p<0.01). 2) The pain score values were significantly higher in group A (p<0.05, p<0.01), 90, 105 and 120 min after skin incision. 3) There was no substantial intraoperative difference in pulse rate and mean arterial pressure between the two groups. 4) A significant decrease in respiratory rate was noted 30 min after skin incision in group A. 5) Blood gases measurement demonstrated no intraoperative changes in PaO₂ values in both groups but a significant PCO₂ increase (p<0.05) in group A, 30 min after skin incision. 6) Nausea, vomiting and shivering rates did not differ significantly between the two groups. 7) Both groups presented a marked progressive descrease in serum Cortisol and prolactin values, 30 and 60 min after skin insicion. Group comparison of corresponding values showed significantly higher serum Cortisol and prolactin values (p<0.05) in group A, 120 min after skin incision. In conclusion our results showed that continuous epidural fentanyl infusion, using a pump, in patients undergoing gynaecological procedures under epidural anaesthesia: 1) prolongs the duration of sensory blockade 2) provides better quality of analgesia 3) protects the patient from respiratory depression 4) decreases the endocrine response due to the regression of the optimal level of anaesthesia intraoperatively.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 1996
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mavrommati, Panorea
- Μαυρομμάτη, Πανωραία
Subjects
dc:subject × 16- Αντλία
- Διεγχειρητική ενδοκρινική απάντηση
- Επισκληρίδιος αναισθησία
- Οπιοειδή
- Συνεχής έγχυση
- Χειρουργικό stress
- Continuous infusion
- Epidural anaesthesia
- Intraoperative endocrine response
- Opioid
- Pump
- Surgical stress
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/6067