Back to search

Aristotle University Of Thessaloniki (AUTH)

Διερεύνηση ενεργειακών και περιβαλλοντικών επιπτώσεων από τη χρήση αντλιών θερμότητας αέρα-νερού σε συστήματα θέρμανσης

Abstract

dc:description

Heat pumps (HPs) are regarded as one of the most efficient, mature, and reliable technologies that utilize renewable energy sources - such as air, water, or ground - to provide heating, cooling, and domestic hot water with no harmful emissions given off locally. Moreover, with the decarbonization of the electricity sector, HPs in combination with thermal storage in heating and cooling systems, may help to balance the differences between the electric energy production from renewable energy sources (RES) and energy demand, playing the role of “thermal batteries”. In particular, air-to-water HPs are expected to replace oil and natural gas boilers on a large scale, especially in urban areas where the installation of geothermal systems is challenging. Their use and application are especially favorable within Greek territory due to the mild climate. The objective of this dissertation is to investigate the energy performance and environmental impacts associated with the operation of air-to-water HPs in heating systems in Greece. The energy performance was examined through the estimation and evaluation of the Seasonal Coefficient of Performance (SCOP) for heating, in accordance with the European Standard EN14825, for each region and climatic zone of Greece. In this way, the energy labeling and energy analysis of air-to-water heat pump heating systems can be achieved more accurately and reliably. The environmental impacts were assessed by estimating the indirect carbon dioxide (CO₂) emissions, resulting from the use of air-to-water HPs and by comparing these with the respective impacts from conventional heating systems based on the combustion of oil or natural gas.An initial analysis of the operational characteristics of a large sample of heat pumps revealed that the evaluation of energy efficiency cannot be reliably achieved using the nominal coefficient of performance (COP) in heating mode. This finding necessitates the study of the seasonal coefficient of performance (SCOP) based on long-term climatic data obtained from local meteorological stations. To this purpose, statistical processing of hourly outdoor air temperature data from 50 meteorological stations of the National Observatory of Athens was conducted for the period 2010–2019. From these data, a temperature database suitable for energy calculations according to the EN14825 standard was developed. In parallel, a software was developed to estimate the seasonal coefficient of performance (SCOP), simulating the operation of heat pumps, accounting for parameters such as regional climate, building construction characteristics, water supply temperature in the heating system, and operational control strategies.The application of the software to 50 Greek cities revealed significant variations in SCOP among different regions, depending on climatic zone and building characteristics. The results highlighted the optimal operating conditions of HPs, including water supply temperature to heating surfaces, the implementation of weather-compensated control, and the sizing of the heat pump relative to the thermal load. Furthermore, the seasonal coefficient of performance (SCOP) for heating was calculated for the HPs included in the software database, across the 50 Greek cities and under various operational and building insulation conditions. The analysis of these results yielded valuable insights regarding the range of variations of the seasonal performance by city and climatic zone, which are presented in graphs, tables, and maps. Finally, the comparative assessment of HPs against conventional fossil-fuel-based heating systems, with respect to their environmental impacts during operation, demonstrated a substantial reduction in indirect CO₂ emissions due to the utilization of ambient thermal energy and the high energy efficiency of HPs. These findings confirm the significant role of heat pumps in achieving a sustainable energy transition.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2026

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Mouzeviris, Georgios
  • Μουζεβίρης, Γεώργιος

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/60922

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Mouzeviris, Georgios; Μουζεβίρης, Γεώργιος. Διερεύνηση ενεργειακών και περιβαλλοντικών επιπτώσεων από τη χρήση αντλιών θερμότητας αέρα-νερού σε συστήματα θέρμανσης. Aristotle University Of Thessaloniki (AUTH), 2026. http://hdl.handle.net/10442/hedi/60922