University of Crete (UOC)
Transpulmonary driving pressure and lung stress during assisted ventilation with PAV+: a prospective observational study
Abstract
dc:descriptionBackgroundIn the setting of controlled mechanical ventilation (CMV), the driving pressure of the respiratory system (ΔPRS) is calculated as the difference between inspiratory plateau pressure (Pplateau) and positive end-expiratory pressure (PEEP), after performing endinspiratory and end-expiratory maneuvers. ΔPRS serves as an indirect measure of static tidal lung stress through transpulmonary driving pressure (ΔPlung) which is defined as the difference in transpulmonary pressure between the end of inspiration and the end of expiration. However, during assisted mechanical ventilation, expiratory muscle activity is frequently present, resulting in decreased end-expiratory lung volume, potentially affect the validity of ΔPRS as a surrogate of ΔPlung. This prospective observational study was conducted in patients with acute respiratory distress syndrome (ARDS) receiving proportional assist ventilation (PAV+) and sought to explore the frequency of increased ΔPlung, to examine the relationship between ΔPRS and ΔPlung, as well as to investigate whether dynamic transpulmonary pressure (Plung,sw) and indices of inspiratory effort (trans-diaphragmatic and respiratory muscle pressure swings) remain within physiologically acceptable limits during assisted mechanical ventilation. Methods A total of thirty-one intubated ARDS patients, all instrumented with esophageal balloon catheters (n=31) and a subset with additional gastric balloon catheters (n=22), were enrolled in the study. The patients included were initially ventilated with CMV and during the weaning phase were transitioned to assisted mechanical ventilation with PAV+. After switching to assisted ventilation, key respiratory variables including flow (V’), airway pressure (Paw), esophageal pressure (Pes) and gastric pressure (Pgas), when available, were continuously recorded for a maximum of 24 hours. In the first phase of the analysis, the occluded breaths from PAV+ were identified using a custom developed program for automatic breath analysis. To minimize the contribution of random breaths with irregular characteristics to the analysis, a 7-breath moving average was applied. In each patient, data were further stratified per deciles of increasing lung elastance (Elung) to explore trends across different respiratory mechanics. In the second part of the analysis patients were divided into two groups according to how end-inspiratory transpulmonary pressure (Plung-EI) changed in relation to Elung. With increasing Elung, Group A exhibited increasing Plung-EI and Group B demonstrated either stable or decreasing Plung-EI. Results Among 44,836 occluded breaths, a ΔPlung ≥ 12 cmH2O was infrequently observed, occurring in a median of 0.0% (IQR: 0.0–16.9%) of measurements. A decrease in end-expiratory lung volume due to active expiration was associated with underestimation of ΔPlung by ΔPRS, as indicated by a negative linear correlation between transpulmonary pressure at end-expiration (Plung-EE) and ΔPlung / ΔPRS ratio. Based on the relationship between Plung-EI and increasing Elung, 17 patients were classified into Group A and 14 patients into Group B. Elung increase was associated with increased ΔPlung. In Group A, ΔPlung was driven by increased Plung-EI. On the other hand, in Group B the increase in ΔPlung was attributed to decreased Plung-EE. While ΔPRS demonstrated acceptable diagnostic performance for detecting ΔPlung ≥ 12 cmH₂O [area under the ROC-curve (AUC): 0.87 (95% CI: 0.82–0.92), p-value < 0.001], this performance was attributed exclusively to Group A [AUC: 0.91 (0.86–0.95), p-value < 0.001]. In Group B, ΔPRS did not show predictive ability for detecting elevated ΔPlung reliably [AUC: 0.65 (0.52–0.78), p-value > 0.05]. During the recorded ventilation period, dynamic transpulmonary pressure (Plung,sw) and indices of inspiratory effort remained mainly within the physiologically acceptable limits.ConclusionIn patients with ARDS ventilated with PAV+, injurious tidal lung stress and inspiratory effort were uncommon. In the presence of expiratory muscle activity, ΔPRS tended to underestimate ΔPlung. This limitation reduces the reliability of using ΔPRS as a surrogate of tidal lung stress, irrespective of the mode of assisted ventilation.
Degree
thesis:*- Grantor dc:publisher
- University of Crete (UOC)
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Stamatopoulou, Vaia
- Σταματοπούλου, Βάια
Subjects
dc:subject × 9Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/62182