National and Kapodistrian University of Athens
Δείκτες μικροκυκλοφορίας και αιμοδυναμική βελτιστοποίηση
Abstract
dc:descriptionChanges in CO2-derived variables during a fluid challenge have been proposed as markers of fluid responsiveness. We investigated whether, instead of fluid administration, passive leg raising (PLR)-induced changes in the CO2-derived variables, namely central venous-arterial carbon dioxide partial pressure (P(cv-a)CO2) and the ratio between P(cv-a)CO2 and the arterial-central venous oxygen content (P(cv-a)CO2/C(a-cv)O2), could detect preload responsiveness in critically ill patients. Methods: We studied 30 mechanically ventilated patients in whom a PLR test was performed due to acute circulatory failure. Routine hemodynamic variables, velocity-time integral (VTI), in the left ventricular outflow tract, and CO2-derived variables, were measured before, during, and after a PLR test. A PLR-induced increase in VTI of ≥10% defined preload responsiveness. The differences (∆) of P(cv-a)CO2 and P(cv-a)CO2/C(a-cv)O2 between PLR and pre-PLR were calculated. The predictive values of PLR-induced changes in the CO2-derived variables was determined by receiver operating characteristic area under curves (ROC-AUCs). Results: Fifteen patients (50%) were classified as preload responsive. ∆P(cv-a)CO2 and ∆P(cv-a)CO2/C(a-cv)O2 were correlated with VTI changes and differed significantly between responders and non responders −1.3 (−2–−0.6) vs. 0.6 (−0.1–1.1) mmHg, p < 0.001, and −0.38 (−0.97–−0.34) vs. 0.1 (−0.15–0.57) mmHg/mL O2, p < 0.001, respectively. The PLR-induced decrease in P(cv-a)CO2 was significantly associated with preload responsiveness (OR 0.48, CI 0.20–0.89, p = 0.016, bootstrap CI 0–0.85). The AUC curves for both ∆P(cv-a)CO2 and ∆P(cv-a)CO2/C(acv)O2 ratio to predict preload responsiveness were 0.89 (CI 0.74–1), p < 0.001, and 0.85 (CI 0.70–1), p < 0.001, respectively. Conclusions: In mechanically ventilated ICU patients with circulatory shock, PLR-induced changes in P(cv-a)CO2 and P(cv-a)CO2/C(a-cv)O2 ratio were correlated with VTI changes. The change in P(cv-a)CO2 was the only variable detecting preload responsiveness assessed by PLR; therefore, it could serve as an indirect marker, useful to guide fluid resuscitation when cardiac output measurement is not feasible.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Baladima, Angeliki
- Μπαλαδήμα, Αγγελική
Subjects
dc:subject × 8Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/62200