dc:description

INTRODUCTION Maxillary molar distalization is a key orthodontic technique for managing Class II malocclusions by moving the upper molars posteriorly. While traditional methods like Cervical Headgear have been widely used, they depend significantly on patient compliance, which may compromise effectiveness. To address this limitation, skeletal anchorage systems have introduced non-compliance protocols that offer greater predictability and control.METHODSThis study combines a narrative review of the literature with a finite element analysis (FEA) to compare the biomechanics of six maxillary molar distalization appliances. The evaluated appliances include: (1) Cervical Headgear, (2) Pendulum appliance (Pend-X), (3) Infrazygomatic mini-screws with fixed appliances, (4) the Advanced Maxillary Distalization Appliance (AMDA), (5) Miniplate-supported distalization (Bollard Appliance), and (6) the Beneslider appliance. Displacements were analyzed in the sagittal, vertical, and transverse dimensions.RESULTSThe analysis revealed that Cervical Headgear resulted in the highest degree of molar tipping. In contrast, the mini-screw and miniplate-supported systems provided superior control, exhibiting minimal tipping and effective intrusion mechanics. The AMDA appliance demonstrated unique capacity in managing transverse arch width, while the Pendulum and Beneslider allowed for controlled extrusion and distal movement.DISCUSSIONThe findings emphasize the importance of appliance selection based on individual treatment goals. Conventional methods may be effective but are limited by compliance, while non-compliance systems offer more consistent biomechanics, especially in cases requiring bodily movement and vertical control. Each appliance carries specific advantages and limitations that should guide clinical decision-making.CONCLUSIONBy integrating insights from literature and finite element modeling, this study offers a comparative biomechanical framework to support orthodontists in choosing appropriate maxillary molar distalization protocols. The results underscore the clinical benefits of skeletal anchorage systems in delivering more controlled and efficient tooth movement.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2026

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kmeid, Roland
  • Κμέιντ, Ρόλαντ

Subjects

dc:subject × 18

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/62226

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kmeid, Roland; Κμέιντ, Ρόλαντ. Comparative analysis of conventional and non-conventional approaches for maxillary molar distalization protocols: a finite element study. Aristotle University Of Thessaloniki (AUTH), 2026. http://hdl.handle.net/10442/hedi/62226