Abstract
dc:descriptionThe subject of the present Thesis is the investigation of concrete-to-concrete interfaces formed at cold joints, with post-installed bars fastened with adhesives or post-installed mechanical connectors, under cyclic actions. The first experimental part of this study addresses twenty-five (25) short interfaces crossed by a small number of connectors subjected to pure shear. The effect of alternative connectors, different diameters, embedment length and interface roughness was investigated. It was observed that different failure modes occur, depending on the different connector types and embedment depths. The positive effect of roughness on the interface resistance was confirmed, but the results indicate that, for very high roughness values, the resistance may be smaller than for moderate values. It was also noticed that the behavior of interfaces crossed by mechanical anchors was less stiff in the ascending branch and exhibited a less steep falling branch. The extension of the project on testing thin overlays showed that the resistance was significantly affected in case of cyclic loading, suggesting that the use of any type of anchor in seismic conditions needs to be supported by adequate experimental evidence. The investigation of interfaces under pure shear was extended to the second experimental part including six (6) long interfaces crossed by a large number of connectors subjected to cyclic shear. Those interfaces represent real practice connections between e.g., a slab and a shear wall or a beam and a wall. The results were compared with those acquired from testing short interfaces of similar characteristics. In long interfaces crossed by reinforcing bars, high shear resistance was reached, accompanied by brittle failure, which was also observed in small-scale interfaces with shallow embeds, thus suggesting that reinforcing bars should be post-installed to concrete at an adequate depth. The failure of rough long interfaces reinforced with mechanical anchors was less brittle, their resistance significantly lower, with a smooth post-peak behavior, and they were able to sustain greater shear slips. The rough interfaces, short or long, reinforced with different connectors, reach their maximum resistance at different shear slips, but, in all cases, at rather small values of slips. For large values of the shear slip, imposed at one end of the interface, the shear slips along it tended to be uniform in long interfaces. The asymmetry of resistance between the two loading directions that was observed in short interfaces was alleviated in the long ones, where also the scatter of the results was limited among duplicate specimens. Recognizing that a major difference exists between the experimental results obtained from testing interfaces under pure shear and the state of forces in interfaces within real retrofitting applications, where the latter is significantly more complex, the decision was made to conduct application tests on half-scale subassemblies consisting of RC frames infilled with a RC wall, a strengthening strategy widely adopted in practice due to its significant benefits. The efficiency of this intervention depends, among others, on the behavior of interfaces between the shear wall and the perimetric frame elements. To investigate the cyclic behavior of interfaces within the composite frame-to-wall members, four (4) frames filled with RC walls, as well as two (2) reference specimens (a bare frame and a monolithic frame/wall specimen), were subjected to cyclic horizontal displacements. The crucial effect of the interface reinforcement ratio and the embedment length on the behavior of the specimens, in terms of maximum capacity, drift, and failure mode, was confirmed. Finally, the experimental investigation of this work was complemented by its analytical component. The design equation and the global model developed at NTUA were evaluated in terms of their ability to predict the maximum interface resistance and to reproduce the full cyclic response for the tests of this Thesis. It was demonstrated that both approaches remain applicable not only to interfaces subjected to pure shear, but also to those under more complex stress states. The global model was implemented in the Python programming language, enabling its practical use and further development. Furthermore, a preliminary numerical investigation of selected subassemblies using nonlinear finite element software yielded promising results for future study.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Oikonomopoulou, Erato
- Οικονομοπούλου, Ερατώ
Subjects
dc:subject × 14- Διεπιφάνειες Ωπλισμένου Σκυροδέματος
- Μετατοποθετούμενα βλήτρα
- Σεισμική ενίσχυση
- Συμπεριφορά σε ανακύκλιση
- Reinforced concrete interfaces
- Post-installed connectors
- Seismic retrofit
- Cyclic behavior
- Επιστήμη Πολιτικού Μηχανικού
- Επιστήμες Μηχανικού και Τεχνολογία
- Δομοστατική
- Civil Engineering
- Engineering and Technology
- Structural Engineering
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/62463