University of West Attica
Η επίδραση της όπτησης οδοντιατρικής πορσελάνης και της συγκλεισιακής φόρτισης στην αυχενική και εσωτερική εφαρμογή των κατασκευασμένων με τη χρήση της τεχνολογίας CAD/CAM σκελετών Co-Cr επιεμφυτευματικών συγκολλούμενων μεταλλοκεραμικών στεφανών
Abstract
dc:descriptionIn this doctoral dissertation, the effect of porcelain firing cycles on the microstructure, as well as on the marginal and internal fit of Co-Cr frameworks of implant-cemented metal-ceramic crowns manufactured by four different fabrication methods: Casting (C), Hard Milling (HM), Soft Milling (SM), and Selective Laser Melting (SLM) was evaluated. Additionally, the effect of occlusal loading on the marginal and internal fit of Co-Cr frameworks of implant-cemented metal-ceramic crowns was assessed. Six (n=6) Co-Cr specimens were fabricated with each of the four manufacturing methods and divided into two subgroups (n=3): one subgroup with the specimens as fabricated (C1, HM1, SM1, SLM1) and the other subgroup (C2, HM2, SM2, SLM2) with specimens subjected to thermal cycles simulating porcelain firings. The microstructure analysis of the Co-Cr specimens was studied using X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Energy Dispersive X-ray Spectroscopy (EDX). Ten (n=10) Co-Cr frameworks of implant-cemented metal-ceramic crowns were fabricated with each manufacturing method, categorized into groups (C, HM, SM, SLM) according to their fabrication method, marginal and internal discrepancies were measured using micro-CT. Occlusal loading was applied to the implant-cemented metal-ceramic crowns of all groups, and the marginal and internal fit was evaluated before and after occlusal loading. The results were analyzed by two-way ANOVA and Tukey post hoc test. The results showed the presence of the two allotropic crystalline phases of cobalt, γ-fcc and ε-hcp, in all specimens; after thermal cycles, the percentage of the ε-hcp phase increased, especially in the C and SM groups. Random distribution of small pores or defects was detected in the C and HM groups and in the SLM1 subgroup, while the SM group specimens showed a diffuse distribution of small pores. Carbides were detected in the C, HM, and SLM groups, also carbides and silica in the SM2 subgroup. After porcelain firings, C and SM groups exhibited a statistically significant (p < 0.05) reduction in marginal and internal discrepancies. Before porcelain firing cycles, SLM and SM groups exhibited better marginal fit with a significant difference (p < 0.05) than the other groups, and the SLM group had better internal fit than the other groups demonstrating statistical significance (p < 0.05). After porcelain firings, the SM group exhibited better marginal and internal fit with statistical significance (p < 0.05) than the other groups. Occlusal loading did not affect the marginal and internal fit of the Co-Cr frameworks. The marginal and internal fit of all groups, both before and after porcelain firings, as well as after occlusal loading, was clinically acceptable.
Degree
thesis:*- Grantor dc:publisher
- University of West Attica
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Nikolopoulos, Michail
- Νικολόπουλος, Μιχαήλ
Subjects
dc:subject × 38- Σχεδιασμός με τη βοήθεια ηλεκτρονικού υπολογιστή/Κατασκευή με τη βοήθεια ηλεκτρονικού υπολογιστή
- Χύτευση
- Επιλεκτική τήξη με λέιζερ
- Σκληρή κοπή
- Μαλακή κοπή
- Σκελετοί κοβαλτίου-χρωμίου
- Μεταλλοκεραμικές στεφάνες
- Επιεμφυτευματικές συγκολλούμενες προσθέσεις
- Αυχενική εφαρμογή
- Εσωτερική εφαρμογή
- Μικροδομή
- Περίθλαση ακτίνων-Χ
- Ηλεκτρονική μικροσκοπία σάρωσης
- Φασματοσκοπία διασποράς ενέργειας ακτίνων-Χ
- Μέθοδος υπολογιστικής μικροτομογραφίας
- Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM)
- Casting
- Selective Laser Melting (SLM)
- Hard milling
- Soft milling
- Co-Cr frameworks
- Metal-ceramic crowns
- Implant-cemented restorations
- Marginal fit
- Internal fit
- Microstructure
- X-ray diffraction (XRD)
- Scanning electron microscopy (SEM)
- Energy Dispersive X-ray spectroscopy (EDX)
- Micro-Computed Tomography (Micro-CT)
- Επιστήμες Υγείας
- Ιατρική και Επιστήμες Υγείας
- Επαγγέλματα υγείας
- Επιστήμες υγείας, άλλοι τομείς
- Health Sciences
- Medical and Health Sciences
- Health Professions
- Health sciences, miscellaneous
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/62876