Aristotle University Of Thessaloniki (AUTH)
Ραδιολογικός χαρακτηρισμός ενεργοποιημένων τμημάτων αντιδραστήρων
Abstract
dc:descriptionThe radiological characterization of activated components of nuclear reactors - resulting from neutron-induced nuclear reactions - which typically also exhibit surface contamination, is essential for decision-making regarding their management during decommissioning activities. Prior to the dismantling or/and segmentation of reactor components, the selection of an appropriate cutting technology, aimed at minimizing the generation of secondary radioactive waste and reducing radiation doses to personnel, relies on accurate radiological characterization of radionuclides both within the volume of materials and on their surfaces as contamination.When decontamination is required prior to dismantling, the precise identification of radionuclides present on the surface and within the volume of materials is crucial for selecting the most appropriate decontamination method. Finally, following dismantling and segmentation, accurate radiological characterization of radionuclides within the materials and on their surfaces is necessary to assess the effectiveness of decontamination, as well as to determine suitable decontamination strategies and clearance procedures.In activated reactor components, certain radionuclides are present within the material matrix (activation products), others are found on the surface as contamination (fission products), and some are present both within the volume and on the surface (soluble activation products). Indicatively, ⁹⁴Nb is highly insoluble, in contrast to ⁶⁰Co, which is soluble, although both are activation products. Consequently, ⁹⁴Nb is not typically observed as surface contamination, whereas the presence of ⁶⁰Co on surfaces is significant. In contrast, ¹³⁷Cs, a fission product, is predominantly found as surface contamination and only rarely within the volume.This doctoral dissertation presents the development of a non-destructive (NDT) γ-spectrometry method, based on Monte Carlo source–detector simulations performed with the MCNP code, for the simultaneous quantitative determination of activation products distributed within materials and radioactive contamination present on their surfaces from a single gamma-spectrometry measurement.For the discrimination and quantification of radioactivity on the surface and within the volume, two alternative, equivalent methods were developed, based on the analysis of the photopeak and the Compton edge. The first method is based on the net counts of the detector in the photopeak and the Compton edge region arising from the contribution of activities in the volume (due to activation) as well as on the surface (due to radioactive contamination) of the steel sample. The second method was based on the relationship between the Compton-to-photopeak ratio (C/P) and the absolute photopeak efficiency, as derived from simulated spectra. This relationship was utilized for the determination of the activity of radionuclides that are present concurrently in the volume and on the surface as contamination in steel samples.Sample configurations consisting of arrays of 1 mm thick steel slabs and filter paper sources contaminated with ¹³⁷Cs of nominal activity were prepared to validate both methods, using both experimental and simulated spectra. Both methodologies produced consistent results and the agreement between the nominal activities and the experimentally determined ones were within the 1σ to 2σ uncertainty level, confirming their reliability for the simultaneous quantification of surface contamination and volume activity in steel from a single measurement.Furthermore, the method was validated using a real activated sample from the Greek Research Reactor (GRR-1). Excellent agreement was demonstrated between the results obtained using the proposed Compton-to-photopeak (C/P) ratio and absolute photopeak efficiency method and those obtained with a certified software package for gamma-spectrometry analysis of samples and containers of arbitrary geometries, which performs efficiency calibration through Monte Carlo modelling without requiring physical calibration with reference radioactive sources.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Markopoulos, Angelos
- Μαρκόπουλος, Άγγελος
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/62939