University of West Attica
Ψηφιακή ακτινογραφία και δείκτης έκθεσης: η ισορροπία μεταξύ ποιότητας εικόνας και απαιτούμενης δόσης ακτινοβολίας και η συμβολή του Τεχνολόγου Ακτινολογίας Ακτινοθεραπείας
Abstract
dc:descriptionThis doctoral thesis investigates one of the most critical issues in contemporary diagnostic radiology: the optimal balance between diagnostic image quality and minimization of the radiation dose received by the patient. The widespread implementation of digital radiographic systems has significantly improved imaging capabilities; however, it has also highlighted the need for systematic monitoring of exposure parameters, avoidance of unnecessary radiation burden, and continuous optimization of radiological practice in accordance with the ALARA (As Low As Reasonably Achievable) principle.Within this context, the Exposure Index (EI) is a quantitative indicator of the radiation incident on the digital detector and is used to assess exposure adequacy and the expected image quality, without constituting a direct measure of patient dose. Its proper interpretation is particularly important, as it contributes to the prevention of overexposure and supports evidence-based decisions regarding the selection of exposure parameters.The aim of the present study was the systematic investigation of the relationship between the Exposure Index and anthropometric, demographic, dosimetric, and geometric factors during posteroanterior chest radiography under real clinical conditions. More specifically, the association of EI with Body Mass Index (BMI), age, sex, source-to-object distance, and Entrance Skin Dose (ESD) was examined, in order to evaluate its usefulness as a tool for optimization and individualization of exposure parameters.The methodology was based on the analysis of 805 chest radiography examinations. The collected data were subjected to statistical analysis using correlation methods and multivariable regression models in order to determine the independent contribution of each factor to variations in EI. The Kolmogorov–Smirnov test was used to assess the normality of quantitative variables, while multiple linear regression and stratified analyses by sex, age, and BMI were performed. The regression results were expressed as regression coefficients (b), 95% confidence intervals (CIs), and p-values, with the level of statistical significance set at p<0.05.The results demonstrated that EI was significantly influenced by BMI, sex, and ESD, while age showed a differentiated effect in the individual analyses. In the overall multivariable model, BMI was negatively associated with EI (b=−10.62, 95% CI: −11.78 to −9.46, p<0.001), whereas female sex (b=14.34, 95% CI: 4.91–23.78, p=0.003) and ESD (b=650.11, 95% CI: 522.45–777.78, p<0.001) were positively associated with EI. Age (p=0.301) and source-to-object distance (SOD) (p=0.697) were not significantly associated with EI in the overall adjusted model. In the sex-stratified analysis, age was positively associated with EI among women (b=0.63, 95% CI: 0.25–1.00, p=0.001), whereas the association was not statistically significant among men (b=−0.25, p=0.057). BMI was negatively associated with EI in both sexes (female: b=−9.64, p<0.001; male: b=−11.57, p<0.001), while ESD was positively associated with EI in both groups (female: b=602.95, p<0.001; male: b=696.98, p<0.001).Increased BMI values were associated with the need to adjust technical exposure parameters in order to maintain diagnostically acceptable image quality. In addition, a moderate positive correlation between EI and ESD was documented, suggesting that EI may function as an indicator of radiation burden tendency, although it cannot replace direct dosimetric assessment. The effect of source-to-object distance further confirmed the importance of geometric parameters in dose management and image quality control.Particular emphasis is placed on the role of the Radiologic Technologist, who is required to correctly interpret EI and appropriately adjust acquisition parameters, thereby ensuring the optimal balance between image quality and radiation protection.The original contribution of this dissertation lies in highlighting the Exposure Index not only as a quality control indicator, but also as a dynamic supporting tool for individualized optimization of radiographic exposure.In conclusion, achieving a balance between image quality and radiation dose is a dynamic and multifactorial process that depends on the patient, technique, acquisition geometry, and the human factor. The findings of this study create the prerequisites for the development of intelligent detectors and algorithm-based exposure management systems adapted to the needs of each individual patient.
Degree
thesis:*- Grantor dc:publisher
- University of West Attica
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Soulis, Petros
- Σούλης, Πέτρος
Subjects
dc:subject × 24- Δείκτης έκθεσης
- Ψηφιακή ακτινογραφία
- Ακτινογραφία θώρακος
- Ποιότητα εικόνας
- Ακτινοπροστασία
- Δόση ακτινοβολίας
- Βελτιστοποίηση έκθεσης
- Δόση εισόδου στο δέρμα
- Exposure Index
- Digital radiography
- Chest radiography
- Image quality
- Radiation protection
- Radiation dose
- Exposure optimization
- Entrance skin dose
- Επιστήμες Υγείας
- Ιατρική και Επιστήμες Υγείας
- Επιστήμες υγείας, άλλοι τομείς
- Επαγγέλματα υγείας
- Health Sciences
- Medical and Health Sciences
- Health sciences, miscellaneous
- Health Professions
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/62943