Abstract
dc:descriptionBackground-Aim. Τhe patients treated with EVAR have outnumbered the patients treated with open surgical repair. Endografts are manufactured by material that is less compliant than the native aortic wall and implantation of them causes decrease in aortic compliance. Increased aortic stiffness is independent prognostic factor for adverse cardiovascular events. Measurement of PWV is the gold standard method for measuring aortic stiffness. The aim of the present study is the investigation of correlation between the length and other properties of endografts used in EVAR and increase of PWV and decrease of aortic compliance. Material and Methods. This is a prospective, monocentric, single-arm observational study. All patients included in the study signed an informed written consent. A detailed medical history of all patients was recorded. Each patient was subjected to a preoperative CTA. DSAs from each EVAR procedure were collected. Details regarding EVAR procedures were recorded too. PWV was measured pre- and post-operatively. Power analysis found that a sample size of 107 patients is required. Primary endpoint was the correlation of endograft length used during EVAR and aortic stiffness increase. If needed, an extension of endografts to external iliac arteries was deployed. Secondary endpoints were the correlation of endograft fabrics and increase of aortic stiffness and PWV, the correlation of EVAR and myocardial and kidney injury during the immediate postoperative period 48 hours. Statistical analysis was conducted SPSS v29.0 software and statistical significance was set at 0.05.Results. The mean age of the patients was 72±7.5 years and 93.5% were males. The mean transverse AAA diameter was 5.7±1.1 cm. Mean endograft length was 169.7±26.9 mm and an extension to external iliac artery was deployed in 10 patients. The mean pre- and post-operative PWV were 10.72±2.07 m/s and 11.93±2.27 m/s respectively. A strong positive correlation was found between endograft length and PWV (p < 0.001). In patients with external iliac artery extension aortic stiffness was increased excessively (t = -4.463 και p = 0.002). No statistically significant difference in PWV was found between the three types of endograft (p = 0.740). Overall 18 patients presented myocardial injury and 26 acute kidney injury. No correlation was found between the length, the type endograft, the extension to external iliac artery, increased PWV and myocardial and kidney injury during the immediate postoperative period. Conclusions. Implantation of endograft during EVAR for AAA management causes increase of aortic stiffness respective to the length of the endograft, while excessive aortic stiffness increase was found in cases with external iliac artery extension. Improvement of the endografts and their manufacturing with more compliant material, which cause lower increase of aortic stiffness and affect the compliance of the native aortic wall in a minimum way, could ameliorate the detrimental effects on the heart and other organs. Larger studies should be conducted in the future so that more reliable conclusions could be reached.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Abatzis-Papadopoulos, Manolis
- Αμπατζής-Παπαδόπουλος, Μανώλης
Subjects
dc:subject × 16- Ανεύρυσμα κοιλιακής αορτής
- Ενδομόσχευμα
- Αορτική σκληρία
- Ταχύτητα σφυγμικού κύματος
- Abdominal aortic aneurysm
- Endograft
- Aortic stiffness
- Pulse wave velocity
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Καρδιολογία και Καρδιοαγγειακά νοσήματα
- Χειρουργική
- Clinical Medicine
- Medical and Health Sciences
- Cardiology and Cardiovascular Medicine
- Surgery
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/63008