Georgia Southern University
Design and Fabrication of a Force-Displacement Control Mechanism for Bone-Surgical Tool Testing
Abstract
dc:description.abstractThis project focuses on the design and fabrication of an experimental setup for orthopedic-tool testing, tailored for a surgical instrumentation company. The multifaceted project encompasses a literature review, conceptual design, prototyping, and rigorous testing, resulting in a versatile control system capable of assessing various orthopedic tools, including bone drills, saws, burrs, and power handpieces. Orthopedic surgical procedures (which include cutting and/or drilling into bone) often need to be performed on bones for faster recovery. The drilling and cutting process can cause an increase in temperature at the cutting site which can cause bone necrosis. The tools also need to be reliable and operate at optimum speeds and loading to increase success rates of surgical procedures. To optimize the cutting conditions, minimize thermal osteonecrosis and, other unwanted damage of bone during surgery; the cutting process, effect of the tool design and cutting parameters on the tool performance need to be investigated. As such, a mechanism for testing the bone-cutting tools is important. The experimental setup integrates state-of-the-art sensors and measurement devices, capturing crucial data such as force, speed, and temperature. A user-friendly control interface enhances operational efficiency, while safety features, ensure user well-being and system integrity. Calibration processes and performance criteria set the stage for comprehensive testing, with iterative feedback loops from stakeholders guiding continuous refinement and documentation finalization. Future work is outlined, including advanced sensor integration, dynamic simulation models, clinical validation studies, and collaborative research initiatives. This project sets the foundation for ongoing advancements in orthopedic tool testing, emphasizing adaptability to emerging technologies and a commitment to improving patient outcomes in bone surgery.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Applied Engineering (M.S.A.E.)
- Level thesis:degree_level
- Thesis (open access)
- Discipline thesis:degree_discipline
- Department of Manufacturing Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Nwagu, Kenneth
- Contributors dc:contributor
-
- Drew Snelling
- Haijun Gong
Subjects
dc:subject × 14- Surgical Instrumentation
- Orthopedics
- Mechatronics
- Bio-Medical Engineering
- Control Systems
- Mechanism design
- Biomedical Devices and Instrumentation
- Computer-Aided Engineering and Design
- Controls and Control Theory
- Electrical and Electronics
- Manufacturing
- Robotics
- Systems and Integrative Engineering
- Systems Engineering
Rights
- Licence dc:rights.license
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.georgiasouthern.edu/etd/2695