University of Guelph
Evaluation of Novel Remote Sensing Techniques for Soil Moisture Monitoring in the Western Canadian Arctic
Abstract
dc:description.abstractRegional soil moisture monitoring from satellite platforms can inform our understanding of climate change in the Canadian Arctic. These sensors require ground-based validation to ensure product accuracy, which can be achieved by upscaling cosmic-ray probe derived soil moisture measurements from an intermediate footprint. Calibration of the cosmic-ray probe installed at Trail Valley Creek, NWT was performed and resulted in an accuracy of 0.019 m3 m-3 RMSE. In addition, a preliminary validation of the Soil Moisture Active Passive (SMAP) soil moisture product was performed. Results indicate a SMAP dry bias at this study site (>0.09 m3 m-3 RMSE). A forward model was employed to determine if SMAP’s bias is a projection or algorithm issue, and results indicate a moderate correlation between SMAP brightness temperature and in situ network brightness temperature (r = 0.44). This demonstrates the potential accuracy improvement made by projecting SMAP soil moisture data on a polar grid in northern latitudes.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Department thesis:degree_department
- Department of Geography
- Grantor dc:publisher
- University of Guelph
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wrona, Elizabeth
- Advisor dc:contributor.advisor
-
- Berg, Aaron
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/10214/10050