dc:description.abstractThe beer brewing industry generates substantial volumes of high organic strength wastewater. As a result, significant over-strength discharge fees (ODFs) can be imposed on breweries by municipalities. This thesis aims to investigate the performance of anaerobic-aerobic (A/O) and combined electrocoagulation and chemical coagulation (EC-CC) treatment in reducing the contaminant load of wastewater generated by a local brewery. Optimal operating parameters for both treatment methods were investigated to enhance removal performance while minimizing operating costs. A/O treatment with two anaerobic and two aerobic columns achieved COD, RP, TSS removal efficiencies of 93.2%, 99.4%, and 97.5%, respectively. Treatment by EC and post-CC at 5W for 20 minutes using aluminum electrodes resulted in COD, RP, TP and TSS removal efficiencies of 26.4%, 74.2%, 75.9%, and 85.1%, respectively. These treatment methods were able to significantly reduce the contaminant load of brewery wastewater demonstrating their potential for ODF reduction and cost savings.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science
- Department thesis:degree_department
- School of Engineering
- Grantor dc:publisher
- University of Guelph
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Swain, Kimberly
- Advisor dc:contributor.advisor
-
- Abbassi, Bassim
Subjects
dc:subject × 7Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10214/15999