Back to search

University of Guelph

Pretreatment Alternatives for the Ultrafiltration of Algae Laden Water

Abstract

dc:description.abstract

The excessive growth of algae from eutrophication as a result of human activities is one of the most serious problems in drinking water treatment. During algae blooms, the excessive release of algae organic matter (AOM) changes the organic matter distributions in surface waters causing severe membrane fouling. Comparisons of the fouling of UF membranes treating surface waters with different natural organic matter (NOM) distributions were done to identify the organic fractions that cause membrane fouling. The waters tested were prepared by combining NOM from Lake Ontario with AOM from four algae species (Chlorella sp., Microcystis aeruginosa, Merismopedia sp., and Cyclotella sp.) commonly found in freshwater. Liquid chromatography-organic carbon detector (LC-OCD) and fluorescence excitation-emission matrix (FEEM) analytical techniques were used to characterize the organic fractions. The membrane fouling was attributed to the hydrophilic fraction of NOM, especially to biopolymer-polysaccharides and proteins as characterized via LC-OCD, and predominant FEEM responses from protein-like and SMP-like substances. The fouling behaviors of the organic fractions were influenced by the addition of natural occurring divalent and metal cations at different doses and pHs. The membrane treating waters with high content of polysaccharides and proteins experienced the highest membrane fouling and membrane resistances. The increase in membrane fouling was attributed to their absorption within the membranes. The addition of divalent cations decreased the membrane fouling as a result of their complexation with AOM. Higher membrane fouling was observed as pH decreased. At pH 6, the membrane experienced the lowest organic matter retention, especially biopolymers and protein-like substances. This was attributable to charge neutralization and reduced electrostatic attraction with the membranes. At pH 8.0, the increase in electrostatic repulsion facilitated the formation of looser layers that led to higher retention of biopolymers and protein-like substances. The fouling behaviors of the organic fractions were compared using sedimentation and dissolved air flotation (DAF) as pre-treatment and influenced by the addition of aluminum and iron-based coagulants. Sedimentation produced better effluent quality than DAF. Membrane fouling decreased with the addition of coagulants, especially aluminum based. Waters with higher biopolymer contents were more susceptible to coagulation achieving higher organic matter removal.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Department thesis:degree_department
School of Engineering
Grantor dc:publisher
University of Guelph
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Castilla Rodriguez, Edwin
Advisor dc:contributor.advisor
  • Zhou, Hongde

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Attribution-ShareAlike 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10214/17698

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Castilla Rodriguez, Edwin. Pretreatment Alternatives for the Ultrafiltration of Algae Laden Water. University of Guelph, 2020. http://hdl.handle.net/10214/17698